Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and ^sup 99m^Tc-tetrofosmin: Method and validation

(ProQuest: ... denotes formulae and/or non-USASCII text omitted; see image) Background The objective of this study was to measure myocardial blood flow (MBF) in humans using 99mTc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Methods Dynamic SPECT using 99mTc-tetrofosmi...

Full description

Saved in:
Bibliographic Details
Published in:Journal of nuclear cardiology Vol. 24; no. 1; p. 268
Main Authors: Shrestha, Uttam, Sciammarella, Maria, Alhassen, Fares, Yeghiazarians, Yerem, Ellin, Justin, Verdin, Emily, Boyle, Andrew, Seo, Youngho, Botvinick, Elias H, Gullberg, Grant T
Format: Journal Article
Language:English
Published: New York Springer Nature B.V 01-02-2017
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:(ProQuest: ... denotes formulae and/or non-USASCII text omitted; see image) Background The objective of this study was to measure myocardial blood flow (MBF) in humans using 99mTc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Methods Dynamic SPECT using 99mTc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99mTc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99mTc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curve ... for K 1 values estimated with 99mTc-tefrofosmin using SPECT and MBF values estimated with 13N-NH3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13N-NH3 PET. The flow-dependent permeability surface-area product (PS) for 99mTc-tefrofosmin was also estimated. Results The estimated flow-extraction parameters for 99mTc-tefrofosmin were found to be A = 0.91 ± 0.11, B = 0.34 ± 0.20 (R 2 = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44-3.81 mL/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (P < .001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (P = .037). The PS for 99mTc-tefrofosmin was (0.019 ± 0.10)*MBF + (0.32 ± 0.16). Conclusions Dynamic cardiac SPECT using 99mTc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF.
ISSN:1071-3581
1532-6551
DOI:10.1007/s12350-015-0320-3