The Vanguard™ endoprotheses were implanted transluminally through the femoral route and deployed at the site of surgically created aneurysms,in the thoracic or abdominal aortas of dogs for prescheduled periods of implantation of 1 week, 1, 2 and 3 months. The in vivo dimensional stability of the endoprothesis was confirmed by angiography after insertion and before the sacrifice and by macroscopic observations after retrieval. Histological and scanning electron microscopic (SEM) studies were perf

Saved in:
Bibliographic Details
Published in:Innovation et technologie en biologie et médecine, une revue de technologie biomédical Vol. 23; no. 4; pp. 212 - 234
Main Authors: Guidoin, R., Douville, Y., Marois, Y., Dionne, G., Guillemot, F., Zhang, Z., King, M.W., Legrand, A.P., Traoré, A., Baquey, C.
Format: Journal Article
Language:English
Published: Elsevier 01-08-2002
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
ISSN:1297-9562
DOI:10.1016/S1297-9562(02)80028-6