Cranio Spinal Irradiation of Medulloblastoma Using High Precision Techniques - A Dosimetric Comparison

Radiotherapy planning, delivery and junction dose verification remain exigent for Cranio Spinal Irradiation (CSI) in medulloblastoma patients. This study aims to evaluate high precision techniques such as Intensity Modulated Radiation Therapy (IMRT), Rapid Arc Therapy (RA) with and without flattenin...

Full description

Saved in:
Bibliographic Details
Published in:Technology in cancer research & treatment
Main Authors: Pichandi, A, Ganesh, K M, Jerrin, A, Balaji, K, Sridhar, P S, Surega, A
Format: Journal Article
Language:English
Published: United States 17-03-2014
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Radiotherapy planning, delivery and junction dose verification remain exigent for Cranio Spinal Irradiation (CSI) in medulloblastoma patients. This study aims to evaluate high precision techniques such as Intensity Modulated Radiation Therapy (IMRT), Rapid Arc Therapy (RA) with and without flattening filter (FF) on the basis of dosimetric analysis. Five patients treated with jagged junction Intensity Modulated RadioTherapy (IMRT) using dynamic Multi Leaf Collimators (MLC) were randomly selected for this retrospective study. IMRT, Rapid Arc (RA) plans were simulated in the same CT data set with and without flattening filter. Total dose prescribed was 28.80 Gy in 16 fractions. An evaluation criterion of 98% of PTV receiving 100% of the prescription dose was followed in all plans. Twenty treatment plans with 260 Dose Volume Histograms (DVHs) was created. Dosimetric parameters such as D , D , D , V , V , CI for PTV and D , D , V , V , V , V for Organs At Risk (OAR) were extracted from DVHs. Treatment delivery efficiency was also evaluated for total Beam On Time (BOT). FFF Rapid Arc therapy (6F_RA) resulted in conformal doses throughout the cranio spinal axis. FF and FFF dynamic IMRT had minimal V107%, 1.23% and 2.88% compared to 49.15 and 66.36 of rapid arc therapy (with and without FF). 6F_IMRT resulted in lesser mean doses to eyes, liver, lungs and kidneys. Heart mean dose was less (3.08 Gy) with 6X_IMRT. Thyroid and esophagus doses could be reduced to about 41.2% and 10% respectively with 6F_RA. The BOT for the treatment techniques were 3.43 min (6X_IMRT), 1.59 min (6F_IMRT), 5min (6X_RA), 4.5 min (6F_RA). Removal of flattening filter in IMRT could improve dose coverage along the caniospinal axis and normal tissue sparing. A reduction of 46.3% BOT could increase treatment efficiency of 6F_IMRT compared to 6X_IMRT. CSI could be simpler since junction doses can be evaded in IMRT and RA techniques.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1533-0338