A comparison of physical activity from Actigraph GT3X+ accelerometers worn on the dominant and non‐dominant wrist

Summary The purpose of this study was to evaluate the agreement between several activity measures using raw acceleration data from accelerometers worn concurrently on the dominant and non‐dominant wrist. Fifty‐five adults (31·9 ± 9·7 years, 26 males) wore two ActiGraph GT3X+ monitors continuously fo...

Full description

Saved in:
Bibliographic Details
Published in:Clinical physiology and functional imaging Vol. 39; no. 1; pp. 51 - 56
Main Authors: Buchan, Duncan S., McSeveney, Fiona, McLellan, Gillian
Format: Journal Article
Language:English
Published: England Wiley Subscription Services, Inc 01-01-2019
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Summary The purpose of this study was to evaluate the agreement between several activity measures using raw acceleration data from accelerometers worn concurrently on the dominant and non‐dominant wrist. Fifty‐five adults (31·9 ± 9·7 years, 26 males) wore two ActiGraph GT3X+ monitors continuously for 1 day, one on their non‐dominant wrist and the other on their dominant wrist. Paired t‐tests were undertaken with sequential Holm‐Bonferroni corrections to compare wear time, moderate‐vigorous physical activity (MVPA), time spent in 10‐min bouts of MVPA (MVPA10 min) and the average magnitude of dynamic wrist acceleration (ENMO). Level of agreement between outcome variables from the wrists was examined using intraclass correlation coefficients (ICC, single measures, absolute agreement) with 95% confidence intervals and limits of agreement (LoA). Time spent across acceleration levels in 40 mg resolution were also examined. There were no significant differences between the non‐dominant and dominant wrist for ENMO, wear time, MVPA or MVPA10 min. Agreement between wrists was strong for most outcomes (ICC ≥0·92) including wear time, ENMO, MVPA, MVPA10 min and the distribution of time across acceleration levels. Agreement was strong in the low acceleration bands (ICC = 0·970 and 0·922) with a mean bias of 3·08 min (LoA −55·18 to 61·34) and −5·43 (LoA −43·47 to 32·62). In summary, ENMO, MVPA, MVPA10 min, wear time and the distribution of time across acceleration levels compared well at the group level. The LOA from the two lowest acceleration levels suggest further work over a longer monitoring period is needed to determine whether outputs from each wrist are comparable.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1475-0961
1475-097X
DOI:10.1111/cpf.12538