Resistance Measurements of BGA Contacts During Reliability Tests
For mechanical fatigue tests were designed special test models of BGA package and test board, for measurements of solder joints and ball contact resistance by four-point method, with elimination of paths resistance. This solution allows the early and partial failures detection. The mechanical fatigu...
Saved in:
Published in: | 2006 29th International Spring Seminar on Electronics Technology pp. 184 - 187 |
---|---|
Main Authors: | , , |
Format: | Conference Proceeding |
Language: | English |
Published: |
IEEE
01-05-2006
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | For mechanical fatigue tests were designed special test models of BGA package and test board, for measurements of solder joints and ball contact resistance by four-point method, with elimination of paths resistance. This solution allows the early and partial failures detection. The mechanical fatigue test was performed on developed mechanical test stand. The resistance was measured before, during and after reliability test. The preliminary results showed that evaluated test method can be applied for accelerated verification of soldering process especially during implementation of lead-free technology. |
---|---|
ISBN: | 9781424405503 1424405505 |
ISSN: | 2161-2528 |
DOI: | 10.1109/ISSE.2006.365382 |