Data acquisition system prototype for Thomson scattering diagnostic of ITER divertor
We present a prototype of the data acquisition system for Thomson scattering diagnostic of ITER divertor. The system allows the recording of the plasma scattered laser radiation beams. They have 1064 nm wavelength, 3 ns duration and 100 Hz - 1 kHz repetition rate. The system consists of 48 simultane...
Saved in:
Published in: | 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC) pp. 1056 - 1059 |
---|---|
Main Authors: | , , , , , |
Format: | Conference Proceeding |
Language: | English |
Published: |
IEEE
01-10-2012
|
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | We present a prototype of the data acquisition system for Thomson scattering diagnostic of ITER divertor. The system allows the recording of the plasma scattered laser radiation beams. They have 1064 nm wavelength, 3 ns duration and 100 Hz - 1 kHz repetition rate. The system consists of 48 simultaneous sampling ADC modules with 10 bit total resolution and 2 GHz sampling rate. The digital units of the ADC modules use FPGA (Field-Programmable Gate Array) for data processing and storage. |
---|---|
ISBN: | 9781467320283 1467320285 |
ISSN: | 1082-3654 2577-0829 |
DOI: | 10.1109/NSSMIC.2012.6551268 |