CT Assessment of Vocal Cord Medialization
Unilateral vocal cord paralysis (UVCP) occurs after iatrogenic injury or disease process and is associated with dysphonia and aspiration. Various surgical options are available for treatment of UVCP, including vocal cord medialization thyroplasty and injection laryngoplasty. These augmentative proce...
Saved in:
Published in: | American Journal of Neuroradiology Vol. 27; no. 8; pp. 1643 - 1646 |
---|---|
Main Authors: | , , |
Format: | Journal Article Conference Proceeding |
Language: | English |
Published: |
Oak Brook, IL
Am Soc Neuroradiology
01-09-2006
American Society of Neuroradiology |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Unilateral vocal cord paralysis (UVCP) occurs after iatrogenic injury or disease process and is associated with dysphonia and aspiration. Various surgical options are available for treatment of UVCP, including vocal cord medialization thyroplasty and injection laryngoplasty. These augmentative procedures improve phonation and airway protection. Our purpose was to demonstrate the CT appearance of implants used for the treatment of UVCP.
Twelve patients treated surgically for UVCP were studied with helical CT. The vocal cords were augmented by using Silastic implants (n = 7), polytetrafluoroethylene (Gore-Tex) implants (n = 2), Teflon injections (n = 2), or fat injection (n = 1). Augmented vocal cords were characterized by size, shape, and Hounsfield units (HU). Two other patients with failed medialization thyroplasty were evaluated for the position of the extruded implant relative to the paralyzed vocal cord.
The 7 Silastic implants were triangular and hyperattenuated (293.4 +/- 90.4 HU). The 2 Gore-Tex implants were heterogeneous with lobulated medial margins and were hyperattenuating (320 and 414 HU). The injected materials demonstrated ovoid/masslike configurations: the 2 Teflon injections were hyperattenuated (107 and 429 HU), and the fat injection was hypoattenuated (-102 HU). Inferior displacement of the implant was demonstrated relative to the true vocal cord in 2 patients with failed Silastic thyroplasties.
CT can distinguish various types of vocal cord augmentation. Silastic implants are recognized by their characteristic triangular configuration. The Gore-Tex implants had unique heterogeneous attenuation with lobulated medial margins. Fat and Teflon injections both appear ovoid/masslike. Teflon injection should not be mistaken for tumor. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0195-6108 1936-959X 1432-1920 |