Conversion of the Kowa RC‐2 camera to a digital version, instructions for use, and postprocessing of the images

OBJECTIVE: To describe a means of converting the Kowa RC‐2 camera to a digital version. PROCEDURE: The optic (OP) and the film portions (FP) of the Kowa RC‐2 were separated. The lateral rails were unscrewed from the front plate of the FP. The front plate was detached from the FP. The plate was fixed...

Full description

Saved in:
Bibliographic Details
Published in:Veterinary ophthalmology Vol. 17; no. 6; pp. 454 - 461
Main Authors: Dulaurent, Thomas, Bath, Alasdair, Isard, Pierre‐François
Format: Journal Article
Language:English
Published: England Blackwell Science 01-11-2014
Blackwell Publishing Ltd
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:OBJECTIVE: To describe a means of converting the Kowa RC‐2 camera to a digital version. PROCEDURE: The optic (OP) and the film portions (FP) of the Kowa RC‐2 were separated. The lateral rails were unscrewed from the front plate of the FP. The front plate was detached from the FP. The plate was fixed to an anodized aluminum plate (AAP). The rails were screwed back onto the front plate. This system was reattached to the OP by means of the rails. A T2‐E mount ring was screwed onto the AAP and fixed to a digital camera body (DCB). A flash sync extension cord was used to connect the flash cable of the Kowa to the DCB. The images obtained with the converted Kowa were inverted horizontally and vertically using image processing software. RESULTS: The images obtained with the converted Kowa RC‐2 were identical in format to those using the film version with a circular image surrounded by a black rectangle. The imaged ocular structures were accurately depicted, appearing upside down and reversed on the LCD screen. The DCB was set to manual mode and focus. The shutter speed was initially set to 1/250 s, and the ISO was adjusted based on the ocular structure being photographed. An extra filter had to be placed over the light source to dim the light when imaging reflective fundi. CONCLUSION: The converted digital version of the Kowa RC‐2 as described provides an affordable means of obtaining high‐quality images of various ocular structures.
Bibliography:http://dx.doi.org/10.1111/vop.12212
ArticleID:VOP12212
ark:/67375/WNG-N353K6SX-N
istex:2CB31CFCD4D45B845BE38E754D3A27E20E4BBE9B
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1463-5216
1463-5224
DOI:10.1111/vop.12212