Vagal response in cryoballoon ablation of atrial fibrillation and autonomic nervous system: Utility of epicardial adipose tissue location
Abstract Background Mechanism and effects of vagal response (VR) during cryoballoon ablation procedure on the cardiac autonomic nervous system (ANS) are unclear. The present study aimed to evaluate the relationship between VR during cryoballoon catheter ablation for atrial fibrillation and ANS modul...
Saved in:
Published in: | Journal of arrhythmia Vol. 33; no. 4; pp. 275 - 282 |
---|---|
Main Authors: | , , , , , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Japan
John Wiley & Sons, Inc
01-08-2017
Elsevier Wiley |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Abstract Background Mechanism and effects of vagal response (VR) during cryoballoon ablation procedure on the cardiac autonomic nervous system (ANS) are unclear. The present study aimed to evaluate the relationship between VR during cryoballoon catheter ablation for atrial fibrillation and ANS modulation by evaluating epicardial adipose tissue (EAT) locations and heart rate variability (HRV) analysis. Methods Forty-one patients with paroxysmal atrial fibrillation (11 with VR during the procedure and 30 without VR) who underwent second-generation cryoballoon ablation were included. EAT locations and changes in HRV parameters were compared between the VR and non-VR groups, using Holter monitoring before ablation, immediately after ablation and one month after ablation. Results The total EAT volume surrounding the left atrium (LA) in the VR and non-VR groups was 29.0±18.4 cm3 vs 27.7±19.7 cm3 , respectively ( p =0.847). The VR group exhibited greater EAT volume overlaying the LA-left superior pulmonary vein (PV) junction (6.1±3.6 cm3 vs 3.6±3.3 cm3 , p =0.039) than the non-VR group. HRV parameters similarly changed following ablation in both the groups. EAT volume overlaying LA-right superior PV junction was significantly correlated with the relative changes in root-mean-square successive differences ( r =−0.317, p =0.043) and high frequency ( r =−0.331, p =0.034), immediately after the ablation. Conclusions Changes in HRV parameters following ablation were similarly observed in both the groups. EAT volume on the LA-PV junction is helpful for interpretation of VR occurrence and ANS modulation. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1880-4276 1883-2148 |
DOI: | 10.1016/j.joa.2017.03.001 |