Influence of extended depth of focus intraocular lenses on visual field sensitivity
To investigate the influence of EDOF IOLs, TECNIS Symfony.sup.® (Johnson & Johnson Surgical Vision, Inc.), on visual field sensitivity and to compare the IOLs with other kinds of IOLs. The subjects included the normal fellow eyes of patients who underwent the Humphrey Field Analyzer (HFA) 30-2 w...
Saved in:
Published in: | PloS one Vol. 15; no. 9; p. e0237728 |
---|---|
Main Authors: | , , , , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
San Francisco
Public Library of Science
14-09-2020
Public Library of Science (PLoS) |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | To investigate the influence of EDOF IOLs, TECNIS Symfony.sup.® (Johnson & Johnson Surgical Vision, Inc.), on visual field sensitivity and to compare the IOLs with other kinds of IOLs. The subjects included the normal fellow eyes of patients who underwent the Humphrey Field Analyzer (HFA) 30-2 with Swedish Interactive Threshold Algorithm Fast within 6 months after cataract due to glaucoma or suspected glaucoma. Each parameter of HFA was compared among eyes implanted with TENIS Symfony.sup.® (EDOF group), diffractive bifocal IOLs (bifocal group), and monofocal IOLs (monofocal group). The total of 76 eyes, including 24 eyes in the EDOF group, 26 eyes in the bifocal group, and 26 eyes in the monofocal group, were included in this study. Mean deviation (MD) of HFA was -0.24±0.58 dB in the EDOF group, -1.38±0.58 dB in the bifocal group, and 0.02±0.44 dB in the monofocal group. Foveal threshold (FT) of HFA was 35.8±1.6 dB in the EDOF group, 33.6±1.7 dB in the bifocal group, and 36.6±1.4 dB in the monofocal group. In both MD and FT, there was significant difference between the bifocal group and the others (p<0.001). There was no difference between the EDOF group and the monofocal group. Moreover, there was no significant difference between the three groups about pattern standard deviation (PSD) of HFA. TECNIS Symfony.sup.® may have little influence on visual field sensitivity, whereas diffractive bifocal IOLs decrease visual field sensitivity. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 Competing Interests: The authors have declared that no competing interests exist. |
ISSN: | 1932-6203 1932-6203 |
DOI: | 10.1371/journal.pone.0237728 |