Vasodilatory capacity and vascular structure in long-standing hypertension: a LIFE substudy

Flow-mediated dilatation (FMD), which is considered a measure of endothelial function, has been found impaired in hypertension. However, it is unclear whether this impairment is explained solely by endothelial dysfunction, or whether it is associated with structural vascular changes and reduced vaso...

Full description

Saved in:
Bibliographic Details
Published in:American journal of hypertension Vol. 15; no. 5; pp. 398 - 404
Main Authors: Olsen, Michael H, Wachtell, Kristian, Aalkjaer, Christian, Dige-Petersen, Harriet, Rokkedal, Jens, Ibsen, Hans
Format: Journal Article
Language:English
Published: New York, NY Elsevier Inc 01-05-2002
Oxford University Press
Elsevier Science
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Flow-mediated dilatation (FMD), which is considered a measure of endothelial function, has been found impaired in hypertension. However, it is unclear whether this impairment is explained solely by endothelial dysfunction, or whether it is associated with structural vascular changes and reduced vasodilatory capacity. In 42 unmedicated patients with hypertension and electrocardiographic left ventricular hypertrophy, we measured the following: 24-h ambulatory blood pressure (BP), minimal forearm vascular resistance (MFVR) by plethysmography, intima-media cross-sectional area of the common carotid arteries (IMA), FMD, and nitroglycerin-induced dilatation (NID) in the brachial artery by ultrasound. We found that FMD was correlated positively with NID (r = 0.38, P < .05). However, FMD as well as NID correlated negatively to 24-h systolic BP (r = −0.41, P = .01 and r = −0.52, P = .001), IMA/height (r = −0.41, P < .01 and r = −0.53, P < .001) and MFVR men (r = −0.44, P < .05 and r = −0.42, P < .05). Low FMD as well as low NID were related in parallel to high systolic BP and to the severity of vascular changes in different vascular beds, suggesting that elevated BP load in hypertension induces parallel abnormalities in conduit artery structure and overall vasodilatory capacity. Therefore, the decrease in FMD observed in severe hypertension may be caused by endothelial dysfunction as well as by structural vascular changes, suggesting difficulties in interpreting FMD solely as a measure of endothelial dysfunction in hypertensive patients with left ventricular hypertrophy.
Bibliography:href:15_5_398.pdf
Supported by grants from The Becket Foundation, The Foundation of Director Jacob Madsen and Olga Madsen and Merck & Co., Copenhagen, Denmark, as part of the LIFE-ICARUS substudy.
istex:904131F7356D780151C3783B0731357FDD5F2053
ark:/67375/HXZ-D4W4LBXT-7
ISSN:0895-7061
1879-1905
1941-7225
DOI:10.1016/S0895-7061(01)02338-X