Quantitative margin assessment of radiofrequency ablation of a solitary colorectal hepatic metastasis using MIRADA RTx on CT scans: a feasibility study
Compared to surgery, radiofrequency ablation(RFA) for colorectal liver metastasis(CRLM) is associated with higher local recurrence(LR) rates. A wide margin (at least 5 mm) is generally recommended to prevent LR, but the optimal method to assess ablation margins is yet to be established. The aim of o...
Saved in:
Published in: | BMC medical imaging Vol. 19; no. 1; p. 71 |
---|---|
Main Authors: | , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
England
BioMed Central Ltd
20-08-2019
BioMed Central BMC |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Compared to surgery, radiofrequency ablation(RFA) for colorectal liver metastasis(CRLM) is associated with higher local recurrence(LR) rates. A wide margin (at least 5 mm) is generally recommended to prevent LR, but the optimal method to assess ablation margins is yet to be established. The aim of our study was to evaluate the feasibility and reproducibility of CT-CT co-registration, using MIRADA software, in order to assess ablation margins of patients with CRLM.
In this retrospective study, pre- and post-ablation contrast-enhanced CT scans of 29 patients, treated with percutaneous RFA for a solitary CRLM, were co-registered. Co-registration was performed by two independent radiologist, based on venous structures in proximity to the tumor. Feasibility of CT-CT co-registration and inter-observer agreement for reproducibility and ablation margins was determined. Furthermore, the minimal ablation margin was compared with the occurrence of LR during follow-up.
Co-registration was considered feasible in 18 patients (61% male, 63.1(±10.9) year), with a perfect inter-observer agreement for completeness of ablation: κ = 1.0(p < 0.001). And substantial inter-observer agreement for measurement of the minimal margin (≤ 0 mm, 1-5 mm, ≥ 5 mm): κ = 0.723(p-value < 0.001). LR occurred in eight of nine(88.9%) incompletely ablated CRLM and in one of the nine completely ablated CRLM(11.1%).
Co-registration using MIRADA is reproducible and potentially a valuable tool in defining technical success. Feasibility of co-registration of pre- and post-ablation CT scans is suboptimal if scans are not acquired concordantly. Co-registration may potentially aid in the prediction of LR after percutaneous ablation. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1471-2342 1471-2342 |
DOI: | 10.1186/s12880-019-0360-2 |