Potential use of V-channel Ge(220) monochromators in X-ray metrology and imaging
While channel‐cut crystals, in which the diffracting surfaces in an asymmetric cut are kept parallel, can provide beam collimation and spectral beam shaping, they can in addition provide beam compression or expansion if the cut is V‐shaped. The compression/expansion ratio depends in this case on the...
Saved in:
Published in: | Journal of applied crystallography Vol. 46; no. 4; pp. 945 - 952 |
---|---|
Main Authors: | , , , , , , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
5 Abbey Square, Chester, Cheshire CH1 2HU, England
International Union of Crystallography
01-08-2013
Blackwell Publishing Ltd |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | While channel‐cut crystals, in which the diffracting surfaces in an asymmetric cut are kept parallel, can provide beam collimation and spectral beam shaping, they can in addition provide beam compression or expansion if the cut is V‐shaped. The compression/expansion ratio depends in this case on the total asymmetry factor. If the Ge(220) diffraction planes and a total asymmetry factor in excess of 10 are used, the rocking curves of two diffractors will have a sufficient overlap only if the second diffractor is tuned slightly with respect to the first one. This study compares and analyses several ways of overcoming this mismatch, which is due to refraction, when the Cu Kα1 beam is compressed 21‐fold in a V21 monochromator. A more than sixfold intensity increase was obtained if the matching was improved either by a compositional variation or by a thermal deformation. This provided an intensity gain compared with the use of a simple slit in a symmetrical channel‐cut monochromator. The first attempt to overcome the mismatch by introducing different types of X‐ray prisms for the required beam deflection is described as well. The performance of the V‐shaped monochromators is demonstrated in two applications. A narrow collimated monochromatic beam obtained in the beam compressing mode was used for high‐resolution grazing‐incidence small‐angle X‐ray scattering measurements of a silicon sample with corrupted surface. In addition, a two‐dimensional Bragg magnifier, based on two crossed V15 channel monochromators in beam expansion mode and tuned by means of unequal asymmetries, was successfully applied to high‐resolution imaging of test structures in combination with a Medipix detector. |
---|---|
Bibliography: | ArticleID:JCRXK5006 istex:8884C848CD5357F83B1773C4AD5939C02A2BFA50 ark:/67375/WNG-LRQJTNJN-W ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 ObjectType-Article-1 ObjectType-Feature-2 Correspondence address: Department of Technology and Diagnostics of Semiconductors, IEE SAS, Vrbovská cesta 110, 921 01 Piešt’any, Slovakia. |
ISSN: | 1600-5767 0021-8898 1600-5767 |
DOI: | 10.1107/S0021889813006122 |