In vitro evaluation of novel antimicrobial coatings for surgical sutures using octenidine
Sutures colonized by bacteria represent a challenge in surgery due to their potential to cause surgical site infections. In order to reduce these type of infections antimicrobially coated surgical sutures are currently under development. In this study, we investigated the antimicrobial drug octenidi...
Saved in:
Published in: | BMC microbiology Vol. 15; no. 1; p. 186 |
---|---|
Main Authors: | , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
England
BioMed Central Ltd
24-09-2015
BioMed Central |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Sutures colonized by bacteria represent a challenge in surgery due to their potential to cause surgical site infections. In order to reduce these type of infections antimicrobially coated surgical sutures are currently under development. In this study, we investigated the antimicrobial drug octenidine as a coating agent for surgical sutures. To achieve high antimicrobial efficacy and required biocompatibility for medical devices, we focused on optimizing octenidine coatings based on fatty acids. For this purpose, antimicrobial sutures were prepared with either octenidine-laurate or octenidine-palmitate at 11, 22, and 33 μg/cm drug concentration normalized per length of sutures. Octenidine containing sutures were compared to the commercial triclosan-coated suture Vicryl® Plus. The release of octenidine into aqueous solution was analyzed and long-term antimicrobial efficacy was assessed via agar diffusion tests using Staphylococcus aureus. For determining biocompatibility, cytotoxicity assays (WST-1) were performed using L-929 mouse fibroblasts.
In a 7 days elution experiment, octenidine-palmitate coated sutures demonstrated much slower drug release (11 μg/cm: 7%; 22 μg/cm: 5%; 33 μg/cm: 33%) than octenidine-laurate sutures (11 μg/cm: 82%; 22 μg/cm: 88%; 33 μg/cm: 87%). Furthermore sutures at 11 μg/cm drug content were associated with acceptable cytotoxicity according to ISO 10993-5 standard and showed, similar to Vicryl® Plus, relevant efficacy to inhibit surrounding bacterial growth for up to 9 days.
Octenidine coated sutures with a concentration of 11 μg/cm revealed high antimicrobial efficacy and biocompatibility. Due to their delayed release, palmitate carriers should be preferred. Such coatings are candidates for clinical testing in regard to their safety and efficacy. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1471-2180 1471-2180 |
DOI: | 10.1186/s12866-015-0523-4 |