Emergency Department Sonographic Measurement of Optic Nerve Sheath Diameter to Detect Findings of Increased Intracranial Pressure in Adult Head Injury Patients

Study objective Our objective is to determine whether a bedside ultrasonographic measurement of optic nerve sheath diameter can accurately predict the computed tomographic (CT) findings of elevated intracranial pressure in adult head injury patients in the emergency department (ED). Methods We condu...

Full description

Saved in:
Bibliographic Details
Published in:Annals of emergency medicine Vol. 49; no. 4; pp. 508 - 514
Main Authors: Tayal, Vivek S., MD, Neulander, Matthew, MD, Norton, H. James, PhD, Foster, Troy, MD, Saunders, Timothy, MD, Blaivas, Michael, MD
Format: Journal Article
Language:English
Published: New York, NY Mosby, Inc 01-04-2007
Elsevier
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Study objective Our objective is to determine whether a bedside ultrasonographic measurement of optic nerve sheath diameter can accurately predict the computed tomographic (CT) findings of elevated intracranial pressure in adult head injury patients in the emergency department (ED). Methods We conducted a prospective, blinded observational study on adult ED patients with suspected intracranial injury with possible elevated intracranial pressure. Exclusion criteria were age younger than 18 years or obvious ocular trauma. Using a 7.5-MHz ultrasonographic probe on the closed eyelids, a single optic nerve sheath diameter was measured 3 mm behind the globe in each eye. A mean binocular optic nerve sheath diameter greater than 5.00 mm was considered abnormal. Cranial CT findings of shift, edema, or effacement suggestive of elevated intracranial pressure were used to evaluate optic nerve sheath diameter accuracy. Results Fifty-nine patients were enrolled in the study. Average age was 38 years, and median Glasgow Coma Scale score was 15 (interquartile 6 to 15). Eight patients with an optic nerve sheath diameter of 5.00 mm or more had CT findings that correlated with elevated intracranial pressure. The sensitivity for the ultrasonography in detecting elevated intracranial pressure was 100% (95% confidence interval [CI] 68% to 100%) and specificity was 63% (95% CI 50% to 76%). The sensitivity of ultrasonography for detection of any traumatic intracranial injury found by CT was 84% (95% CI 60% to 97%) and specificity was 73% (95% CI 59% to 86%). Conclusion Bedside ED optic nerve sheath diameter ultrasonography has potential as a sensitive screening test for elevated intracranial pressure in adult head injury.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0196-0644
1097-6760