Characterization of a Novel Symptom of Advanced Heart Failure: Bendopnea
Objectives This study sought to examine the frequency and hemodynamic correlates of shortness of breath when bending forward, a symptom we have termed “bendopnea.” Background Many heart failure patients describe bendopnea such as when putting on their shoes. This symptom has not previously been char...
Saved in:
Published in: | JACC. Heart failure Vol. 2; no. 1; pp. 24 - 31 |
---|---|
Main Authors: | , , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
United States
Elsevier Inc
01-02-2014
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Objectives This study sought to examine the frequency and hemodynamic correlates of shortness of breath when bending forward, a symptom we have termed “bendopnea.” Background Many heart failure patients describe bendopnea such as when putting on their shoes. This symptom has not previously been characterized. Methods We conducted a prospective study of 102 subjects with systolic heart failure referred for right-heart catheterization. Time to onset of bendopnea was measured prior to catheterization. Forty-six subjects also underwent hemodynamic assessment when sitting and bending. Hemodynamic profiles were assigned on the basis of whether pulmonary capillary wedge pressure (PCWP) was ≥22 mm Hg and cardiac index (CI) was ≤2.2 l/min/m2. Results Bendopnea was present in 29 of 102 (28%) subjects with median (25th, 75th percentiles) time to onset of 8 (7, 11) seconds. Subjects with bendopnea had higher supine right atrial pressure (RAP) (p = 0.001) and PCWP (p = 0.0004) than those without bendopnea but similar CI (p = 0.2). RAP and PCWP increased comparably in subjects with and without bendopnea when bending, but CI did not change. In those with, versus without, bendopnea, there was more than a 3-fold higher frequency of a supine hemodynamic profile consisting of elevated PCWP with low CI (55% vs. 16%, respectively, p < 0.001) but no association with a profile of elevated PCWP with normal CI (p = 0.95). Conclusions Bendopnea is mediated via a further increase in filling pressures during bending when filling pressures are already high, particularly if CI is reduced. Awareness of bendopnea should improve noninvasive assessment of hemodynamics in subjects with heart failure. |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Undefined-1 ObjectType-Feature-3 content type line 23 |
ISSN: | 2213-1779 2213-1787 |
DOI: | 10.1016/j.jchf.2013.07.009 |