Digital reporting of whole-slide images is safe and suitable for assessing organ quality in preimplantation renal biopsies

Summary Digital pathology allows networks of “remote” specialist pathologists to report the findings of preimplantation kidney biopsies. We sought to validate the assessment of preimplantation kidney transplant biopsies for diagnostic purposes using whole-slide images according to the recommendation...

Full description

Saved in:
Bibliographic Details
Published in:Human pathology Vol. 47; no. 1; pp. 115 - 120
Main Authors: Eccher, Albino, MD, PhD, Neil, Desley, MD, Ciangherotti, Andrea, MD, Cima, Luca, MD, Boschiero, Luigino, MD, Martignoni, Guido, Prof, Ghimenton, Claudio, MD, Chilosi, Marco, Prof, Giobelli, Luca, Eng, Zampicinini, Laura, DSN, Casartelli, Marilena, MD, Brunelli, Matteo, Prof
Format: Journal Article
Language:English
Published: United States Elsevier Inc 01-01-2016
Elsevier Limited
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Summary Digital pathology allows networks of “remote” specialist pathologists to report the findings of preimplantation kidney biopsies. We sought to validate the assessment of preimplantation kidney transplant biopsies for diagnostic purposes using whole-slide images according to the recommendations of the College of American Pathologists. Sixty-two consecutive, previously reported, preimplantation kidney biopsies were scanned using the ScanScope Digital Slide Scanner at 0.5 μ m/pixel (20× objective). The slides were assessed for percent glomerulosclerosis, tubular atrophy, interstitial fibrosis and vascular narrowing using the Remuzzi criteria by two pathologists, one using glass slides and the other using the whole-slide images viewed on a widescreen computer monitor. After a 2-week washout period, all of the slides were re-assessed by the same pathologists using the opposite mode of reporting to that used in the first evaluation. Very high glass-digital intraobserver concordance was achieved for the overall score and for individual grades by both pathologists ( κ range, 0.841-0.973). The overall scores obtained by both pathologists and using both methods were identical. The times needed to assess the biopsies were 14 minutes when using a light microscope and 18 minutes, including scanning time, which averaged 2 minutes 20 seconds per slide, when using digital microscopy. Digital microscopy is a reliable, fast, and safe method for the assessment of preimplantation kidney biopsies.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0046-8177
1532-8392
DOI:10.1016/j.humpath.2015.09.012