Digital anatomical study and clinical application of screw placement for quadrilateral plate fractures in the danger zone

Direct screw placement for quadrilateral plate fractures in the danger zone of the acetabulum is very difficult. This study was performed to simulate the surgical procedure and try to obtain effective and safe screw angles through the middle window of the ilioinguinal approach in Chinese patients. W...

Full description

Saved in:
Bibliographic Details
Published in:BMC musculoskeletal disorders Vol. 21; no. 1; p. 222
Main Authors: Zhao, Bei, Sun, Zhongye, Zhang, Wei, Xu, Zhongbao, Yang, Xiaofei, Mu, Weidong
Format: Journal Article
Language:English
Published: England BioMed Central Ltd 11-04-2020
BioMed Central
BMC
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Direct screw placement for quadrilateral plate fractures in the danger zone of the acetabulum is very difficult. This study was performed to simulate the surgical procedure and try to obtain effective and safe screw angles through the middle window of the ilioinguinal approach in Chinese patients. We randomly collected the pelvic computed tomography (CT) scans of 100 adults. DICOM-formatted CT-scan images were imported into Mimics software. The three-dimensional reconstruction (3D) digital model of the semi-pelvis was established. A 3.5 mm cylinder was used to simulate the pathway of the screw from the designated insertion point. The angles of insertion and intersex differences were explored by statistical analyses. The screws could be inserted via three angles: medial inclination, anterior inclination and posterior inclination. The mean minimum medial inclination angle (MIMIA) of insertion point A was 4.96° ± 1.11° in males and 8.66° ± 3.40° in females, and the intersex difference was significant. The mean minimum medial inclination angle (MIMIA) of insertion point B was - 5.31° ± 3.69° in males and 1.75° ± 8.95° in females, and the intersex difference was significant. There were no differences between any of the angles for males and females at insertion point O. Preoperative measurement and calculation by digital tools before screw placement for quadrilateral plate fractures of the acetabulum are feasible. Double cortical screws could be placed safely in the danger zone through the middle window of the ilioinguinal approach to increase the stability of the acetabulum.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1471-2474
1471-2474
DOI:10.1186/s12891-020-03265-7