A prospective clinical pilot study on the effects of a hydrogen peroxide mouthrinse on the intraoral viral load of SARS-CoV-2

Objectives SARS-CoV-2 is mainly transmitted by inhalation of droplets and aerosols. This puts healthcare professionals from specialties with close patient contact at high risk of nosocomial infections with SARS-CoV-2. In this context, preprocedural mouthrinses with hydrogen peroxide have been recomm...

Full description

Saved in:
Bibliographic Details
Published in:Clinical oral investigations Vol. 24; no. 10; pp. 3707 - 3713
Main Authors: Gottsauner, Maximilian J., Michaelides, Ioannis, Schmidt, Barbara, Scholz, Konstantin J., Buchalla, Wolfgang, Widbiller, Matthias, Hitzenbichler, Florian, Ettl, Tobias, Reichert, Torsten E., Bohr, Christopher, Vielsmeier, Veronika, Cieplik, Fabian
Format: Journal Article
Language:English
Published: Berlin/Heidelberg Springer Berlin Heidelberg 01-10-2020
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objectives SARS-CoV-2 is mainly transmitted by inhalation of droplets and aerosols. This puts healthcare professionals from specialties with close patient contact at high risk of nosocomial infections with SARS-CoV-2. In this context, preprocedural mouthrinses with hydrogen peroxide have been recommended before conducting intraoral procedures. Therefore, the aim of this study was to investigate the effects of a 1% hydrogen peroxide mouthrinse on reducing the intraoral SARS-CoV-2 load. Methods Twelve out of 98 initially screened hospitalized SARS-CoV-2-positive patients were included in this study. Intraoral viral load was determined by RT-PCR at baseline, whereupon patients had to gargle mouth and throat with 20 mL of 1% hydrogen peroxide for 30 s. After 30 min, a second examination of intraoral viral load was performed by RT-PCR. Furthermore, virus culture was performed for specimens exhibiting viral load of at least 10 3 RNA copies/mL at baseline. Results Ten out of the 12 initially included SARS-CoV-2-positive patients completed the study. The hydrogen peroxide mouthrinse led to no significant reduction of intraoral viral load. Replicating virus could only be determined from one baseline specimen. Conclusion A 1% hydrogen peroxide mouthrinse does not reduce the intraoral viral load in SARS-CoV-2-positive subjects. However, virus culture did not yield any indication on the effects of the mouthrinse on the infectivity of the detected RNA copies. Clinical relevance The recommendation of a preprocedural mouthrinse with hydrogen peroxide before intraoral procedures is questionable and thus should not be supported any longer, but strict infection prevention regimens are of paramount importance. Trial registration German Clinical Trials Register (ref. DRKS00022484)
ISSN:1432-6981
1436-3771
DOI:10.1007/s00784-020-03549-1