Evaluation of neovessels in atherosclerotic plaques of rabbits using an albumin-binding intravascular contrast agent and MRI
Purpose To test whether B‐22956/1, a novel intravascular contrast agent with a high affinity to serum albumin (Bracco Imaging SpA.), allowed quantifying neovessel and macrophage density in atherosclerotic plaques of rabbits using MRI. Materials and Methods A T1‐weighted MRI of the aorta was acquired...
Saved in:
Published in: | Journal of magnetic resonance imaging Vol. 27; no. 6; pp. 1406 - 1411 |
---|---|
Main Authors: | , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Hoboken
Wiley Subscription Services, Inc., A Wiley Company
01-06-2008
Wiley-Blackwell |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Purpose
To test whether B‐22956/1, a novel intravascular contrast agent with a high affinity to serum albumin (Bracco Imaging SpA.), allowed quantifying neovessel and macrophage density in atherosclerotic plaques of rabbits using MRI.
Materials and Methods
A T1‐weighted MRI of the aorta was acquired in 10 rabbits (7 atherosclerotic and 3 control rabbits) before and up to 2 h after intravenous injection of 100 μmol/kg of Gd‐DTPA or 75 μmol/kg of B‐22956/1. Plaque enhancement was measured at different time points. Immunohistochemistry was performed using anti‐CD 31 antibodies and anti‐RAM 11 antibodies to correlate to neovessel and macrophage density, respectively.
Results
MRI showed a significant plaque enhancement 2 h after B‐22956/1 versus Gd‐DTPA in the atherosclerotic group (39.75% versus 9.5%; P < 0.0001. Early atherosclerotic plaques (n = 146) enhancement positively correlates with neovessel density on corresponding histological sections (r = 0.42; P < 0.01). Enhancement of atherosclerotic plaques 2 h after injection of B‐22956/1 correlated with macrophage density (r = 0.71; P < 0.01).
Conclusion
Enhancement of atherosclerotic plaques with MRI correlated with neovessel density at early time points after the injection of B‐22956/1 and with macrophage density, at later time points. Hence, B‐22956/1‐enhanced MRI represents a promising imaging technique for the identification of “high‐risk” plaques. J. Magn. Reson. Imaging 2008;27:1406–1411. © 2008 Wiley‐Liss, Inc. |
---|---|
Bibliography: | NIH/NHLBI - No. R01 HL71021; No. R01 HL78667 ark:/67375/WNG-WD7P7S6G-9 istex:1AE0F9AA2464E6D8DD7F97A970E9E48CF870051E Federation Française de Cardiologie ArticleID:JMRI21369 ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 PMCID: PMC4415534 |