Striving to be the fittest: quantitative P2/N95 respirator fit test results among hospital staff during the COVID-19 pandemic
To provide fit rates for specific P2/N95 respirators and compare these results by age, sex, clean-shaven status, and fit tester experience. Exploratory audit involving secondary analysis of existing quantitative fit testing data. In response to the COVID-19 pandemic, healthcare services across Austr...
Saved in:
Published in: | Antimicrobial stewardship & healthcare epidemiology : ASHE Vol. 3; no. 1; p. e233 |
---|---|
Main Authors: | , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
England
Cambridge University Press
2023
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | To provide fit rates for specific P2/N95 respirators and compare these results by age, sex, clean-shaven status, and fit tester experience.
Exploratory audit involving secondary analysis of existing quantitative fit testing data.
In response to the COVID-19 pandemic, healthcare services across Australia implemented respiratory protection protocols. This study details healthcare workers' (HCWs) fit testing results from a large Victorian public health service.
Fit-tested employees of a large tertiary public health network.
Fit rates for ten individual P2/N95 respirators were calculated, and the effect of age, sex, clean-shaven status, and fit tester experience was examined via logistic regression.
4593 employees were included, with 97.98% successfully fitting at least one respirator. Males were found to have significantly increased odds of achieving fit success compared to females (OR 11.61 95%CI 1.60-84.10). Fit rates dropped by 4% with each 1-year age increase (OR 0.96 95%CI 0.94-0.98). Clean-shaven individuals were also more likely to achieve a fit compared to non-clean-shaved individuals (OR 79.23 95%CI 10.21-614.62). More experienced fit testers also yielded significantly higher fit rates (OR 3.95, 95%CI 2.34-6.67).
98% of staff achieved a successful fitting of at least one respirator, with three-panel flat fold models (Industree Trident, 3M Aura 9320A+, and 3M Aura 1870+) performing the most consistently. An individual's ability to achieve a successful fit was associated with; male sex, younger age, clean-shaven status, and fit tester experience. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 2732-494X 2732-494X |
DOI: | 10.1017/ash.2023.503 |