Changes in Vertebral Artery Blood Flow Following Various Head Positions and Cervical Spine Manipulation

Abstract Objective The objective of the study was to investigate the cerebrovascular hemodynamic response of cervical spine positions including rotation and cervical spine manipulation in vivo using magnetic resonance imaging technology on the vertebral artery (VA). Methods This pilot study was cond...

Full description

Saved in:
Bibliographic Details
Published in:Journal of manipulative and physiological therapeutics Vol. 37; no. 1; pp. 22 - 31
Main Authors: Quesnele, Jairus J., DC, Triano, John J., DC, PhD, Noseworthy, Michael D., PhD, Wells, Greg D., PhD
Format: Journal Article
Language:English
Published: United States Mosby, Inc 2014
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Objective The objective of the study was to investigate the cerebrovascular hemodynamic response of cervical spine positions including rotation and cervical spine manipulation in vivo using magnetic resonance imaging technology on the vertebral artery (VA). Methods This pilot study was conducted as a blinded examiner cohort with 4 randomized clinical tasks. Ten healthy male participants aged 24 to 30 years (mean, 26.8 years) volunteered to participate in the study. None of the participants had a history of disabling neck, arm, or headache pain within the last 6 months. They did not have any current or history of neurologic symptoms. In a neutral head position, physiologic measures of VA blood flow and velocity at the C1-2 spinal level were obtained using phase-contrast magnetic resonance imaging after 3 different head positions and a chiropractic upper cervical spinal manipulation. A total of 30 flow-encoded phase-contrast images were collected over the cardiac cycle, in each of the 4 conditions, and were used to provide a blood flow profile for one complete cardiac cycle. Differences between flow (in milliliters per second) and velocity (in centimeters per second) variables were evaluated using repeated-measures analysis of variance. Results The side-to-side difference between ipsilateral and contralateral VA velocities was not significant for either velocities ( P = .14) or flows ( P = .19) throughout the conditions. There were no other interactions or trends toward a difference for any of the other blood flow or velocity variables. Conclusions There were no significant changes in blood flow or velocity in the vertebral arteries of healthy young male adults after various head positions and cervical spine manipulations.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-News-1
ObjectType-Feature-3
content type line 23
ISSN:0161-4754
1532-6586
DOI:10.1016/j.jmpt.2013.07.008