Propensity-Matched Patient-Level Comparison of the TAXUS Liberté and TAXUS Element (ION) Paclitaxel -Eluting Stents

Stent design, metal alloy composition, and strut thickness may influence late lumen loss and clinical outcomes after bare metal stent deployment; however, their impact on outcomes after drug-eluting stent deployment is unknown. Although the TAXUS Liberté and ION paclitaxel-eluting stents use similar...

Full description

Saved in:
Bibliographic Details
Published in:The American journal of cardiology Vol. 108; no. 6; pp. 828 - 837
Main Authors: Kereiakes, Dean J., MD, Cannon, Louis A., MD, Ormiston, John A., MBChB, Turco, Mark A., MD, Mann, Tift, MD, Mishkel, Gregory J., MD, McGarry, Thomas, MD, Wang, Hong, MS, Underwood, Paul, MD, Dawkins, Keith D., MD
Format: Journal Article
Language:English
Published: New York, NY Elsevier Inc 15-09-2011
Elsevier
Elsevier Limited
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Stent design, metal alloy composition, and strut thickness may influence late lumen loss and clinical outcomes after bare metal stent deployment; however, their impact on outcomes after drug-eluting stent deployment is unknown. Although the TAXUS Liberté and ION paclitaxel-eluting stents use similar polymer and drug, the ION stent incorporates a novel thin-strut platinum chromium metal alloy and cell design. We therefore compared patient-level data from 2,298 subjects enrolled into the TAXUS ATLAS (TAXUS Liberté) and PERSEUS (ION) clinical trials. Propensity-score (1:1) matching was performed to adjust for covariate imbalance between stent types. Twelve-month major adverse cardiac events were less frequent after use of the ION compared to the TAXUS Liberté (12.7% vs 8.3%, p <0.001, unadjusted; 12.0% vs 7.5%, p = 0.007, propensity matched) largely because of decreased non–Q-wave myocardial infarction (MI; 2.9% vs 1.4%, p = 0.01, unadjusted; 3.2% vs 0.9%, p = 0.004, propensity matched). The MI difference was predominantly periprocedural and in patients treated with a single stent. In conclusion, this exploratory post hoc analysis demonstrated that the ION was associated with fewer adverse clinical events than the TAXUS Liberté because of decreased non–Q-wave MI. Stent platform-related variables may influence clinical outcomes after drug-eluting stent use despite similar polymer and drug elution. Differences in adjunctive pharmacotherapy and/or stenting technique may also be contributory.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0002-9149
1879-1913
DOI:10.1016/j.amjcard.2011.05.011