Pediatric craniospinal irradiation with a short partial-arc VMAT technique for medulloblastoma tumors in dosimetric comparison

Abstract Background This study aimed to contrast four different irradiation methods for pediatric medulloblastoma tumors in a dosimetric comparison regarding planning target volume (PTV) coverage and sparing of organs at risk (OARs). Methods In sum 24 treatment plans for 6 pediatric patients were re...

Full description

Saved in:
Bibliographic Details
Published in:Radiation oncology (London, England) Vol. 15; no. 1; pp. 1 - 10
Main Authors: Pollul, Gerhard, Bostel, Tilman, Grossmann, Sascha, Akbaba, Sati, Karle, Heiko, Stockinger, Marcus, Schmidberger, Heinz
Format: Journal Article
Language:English
Published: London BioMed Central 05-11-2020
BMC
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Background This study aimed to contrast four different irradiation methods for pediatric medulloblastoma tumors in a dosimetric comparison regarding planning target volume (PTV) coverage and sparing of organs at risk (OARs). Methods In sum 24 treatment plans for 6 pediatric patients were realized. Besides the clinical standard of a 3D-conformal radiotherapy (3D-CRT) treatment plan taken as a reference, volumetric modulated arc therapy (VMAT) treatment plans (“VMAT_AVD” vs. “noAVD” vs. “FullArc”) were optimized and calculated for each patient. For the thoracic and abdominal region, the short partial-arc VMAT_AVD technique uses an arc setup with reduced arc-length by 100°, using posterior and lateral beam entries. The noAVD uses a half 180° (posterior to lateral directions) and the FullArc uses a full 360° arc setup arrangement. The prescription dose was set to 35.2 Gy. Results We identified a more conformal dose coverage for PTVs and a better sparing of OARs with used VMAT methods. For VMAT_AVD mean dose reductions in organs at risk can be realized, from 16 to 6.6 Gy, from 27.1 to 8.7 Gy and from 8.0 to 1.9 Gy for the heart, the thyroid and the gonads respectively, compared to the 3D-CRT treatment method. In addition we have found out a superiority of VMAT_AVD compared to the noAVD and FullArc trials with lower exposure to low-dose radiation to the lungs and breasts. Conclusions With the short partial-arc VMAT_AVD technique, dose exposures to radiosensitive OARS like the heart, the thyroid or the gonads can be reduced and therefore, maybe the occurrence of late sequelae is less likely. Furthermore the PTV conformity is increased. The advantages of the VMAT_AVD have to be weighed against the potentially risks induced by an increased low dose exposure compared to the 3D-CRT method.
ISSN:1748-717X
1748-717X
DOI:10.1186/s13014-020-01690-5