Fluorescent determination of chloride in nanoliter samples

Fluorescent determination of chloride (Cl-) in nanoliter samples. Measurements of Cl- in nanoliter samples, such as those collected during isolated, perfused tubule experiments, have been difficult, somewhat insensitive, and/or require custom-made equipment. We developed a technique using a fluoresc...

Full description

Saved in:
Bibliographic Details
Published in:Kidney international Vol. 55; no. 1; pp. 321 - 325
Main Authors: García, Néstor H., Plato, Craig F., Garvin, Jeffrey L.
Format: Journal Article Conference Proceeding
Language:English
Published: New York, NY Elsevier Inc 01-01-1999
Nature Publishing
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Fluorescent determination of chloride (Cl-) in nanoliter samples. Measurements of Cl- in nanoliter samples, such as those collected during isolated, perfused tubule experiments, have been difficult, somewhat insensitive, and/or require custom-made equipment. We developed a technique using a fluorescent Cl- indicator, 6-methoxy-N-(3-sulfopropyl) quinolinium (SPQ), to make these measurements simple and reliable. This is a simple procedure that relies on the selectivity of the dye and the fact that Cl-quenches its fluorescence. To measure millimolar quantities of Cl- in nanoliter samples, we prepared a solution of 0.25 mM SPQ and loaded it into the reservoir of a continuous-flow ultramicrofluorometer, which can be constructed from commercially available components. Samples were injected with a calibrated pipette via an injection port, and the resultant peak fluorescent deflections were recorded. The deflections represent a decrease in fluorescence caused by the quenching effect of the Cl- injected. The method yielded a linear response with Cl- concentrations from 5 to 200 mM NaCl. The minimum detectable Cl- concentration was approximately 5 mM. The coefficient of variation between 5 and 200 mM was 1.7%. Resolution, defined as two times the standard error divided by the slope, between 10 and 50 mM and between 50 and 200 mM was 1 mM and 2.6 mM, respectively. Furosemide, diisothiocyanostilbene-2,2′-disulfonic acid and other nonchloride anions (HEPES, HCO3, SO4, and PO4) did not interfere with the assay, whereas 150 mM NaBr resulted in a peak height greater than 150 NaCl. In addition, the ability to measure Cl- did not vary with pH within the physiological range. We developed an easy, accurate, and sensitive method to measure Cl- concentration in small aqueous solution samples.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0085-2538
1523-1755
DOI:10.1046/j.1523-1755.1999.00239.x