Video observation to map hand contact and bacterial transmission in operating rooms

Background Hand hygiene (HH) is considered a primary intervention to avoid transmission of bacteria in health care settings and to prevent health care-associated infections. Despite efforts to decrease the incidence of health care-associated infections by improving HH, HH compliance rates vary widel...

Full description

Saved in:
Bibliographic Details
Published in:American journal of infection control Vol. 42; no. 7; pp. 698 - 701
Main Authors: Rowlands, John, MD, Yeager, Mark P., MD, Beach, Michael, MD, PhD, Patel, Hetal M., BS, Huysman, Bridget C., BA, Loftus, Randy W., MD
Format: Journal Article
Language:English
Published: New York, NY Mosby, Inc 01-07-2014
Elsevier
Mosby-Year Book, Inc
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background Hand hygiene (HH) is considered a primary intervention to avoid transmission of bacteria in health care settings and to prevent health care-associated infections. Despite efforts to decrease the incidence of health care-associated infections by improving HH, HH compliance rates vary widely depending on the hospital environment. Methods We used intraoperative video observation to map temporal patterns of anesthesia provider hand contact with anesthesia work environment (AWE) surfaces and to assess HH compliance. Serial bacterial cultures of high contact objects were subsequently used to characterize bacterial transmission over time. Results Using World Health Organization criteria, we found a large number of HH opportunities and a low rate of HH compliance by anesthesia providers (mean, 2.9%). We observed an inverse correlation between provider hand hygiene compliance during induction and emergence from anesthesia (3.2% and 4.1%, respectively) and the magnitude of AWE surface contamination (103 and 147 CFU, respectively) at these time points. We found no correlation between frequency of hand contact with the AWE and bacterial contamination. Conclusions Compliance with current HH recommendations by anesthesia providers is not feasible. However, there does appear to be a correlation between HH compliance rates and bacterial contamination of the AWE, an observation that should stimulate further work to design new methods for control of bacterial transmission in operating rooms.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0196-6553
1527-3296
DOI:10.1016/j.ajic.2014.02.021