Luminescent determination of flavonoids in orange juices by LC with post-column derivatization with aluminum and terbium

A new post-column derivatization system is described and applied to the determination of flavonoids in citric beverages after their separation by LC using a monolithic column. The derivatization involves the formation of the chelates of the analytes with aluminum (III) and terbium (III) in the prese...

Full description

Saved in:
Bibliographic Details
Published in:Journal of separation science Vol. 33; no. 4-5; pp. 509 - 515
Main Authors: Andreu-Navarro, Alvaro, Fernández-Romero, Juan Manuel, Gómez-Hens, Agustina
Format: Journal Article
Language:English
Published: Weinheim Wiley-VCH Verlag 01-03-2010
WILEY-VCH Verlag
WILEY‐VCH Verlag
Wiley
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A new post-column derivatization system is described and applied to the determination of flavonoids in citric beverages after their separation by LC using a monolithic column. The derivatization involves the formation of the chelates of the analytes with aluminum (III) and terbium (III) in the presence of the surfactant SDS and the measurement of the terbium sensitized luminescence at λex 360 and λem 545 nm. Naringin, hesperidin, quercetin, naringenin, and kaempferol have been chosen as analyte models. The large Stokes shift and the relatively long wavelength emission of terbium(III) can minimize interferences from background sample matrix, which usually emit at shorter wavelengths. Calibration graphs were constructed in the intervals 6.0-1700 ng/mL naringin, 9.8-1700 ng/mL hesperidin, 2.1-2000 ng/mL quercetin, 5.2-1500 ng/mL naringenin and 2.5-2000 ng/mL kaempferol, with regression coefficients higher than 0.9935 in all instances. The precision of the method, expressed as RSD%, was established at two concentration levels, with values of 1.3 and 4.7%, which corresponded to the minimal and maximal error zones of the calibration graphs. The practical usefulness of the method is demonstrated by the analysis of orange juices, which were diluted and directly injected into the chromatographic system, obtaining recoveries between 86.9 and 108.2%.
Bibliography:http://dx.doi.org/10.1002/jssc.200900696
Junta de Andalucía - No. PO6-FQM-01356
Spanish MCyT (Ministerio de Ciencia y Tecnología) - No. CTQ2009-08621/BQU
ArticleID:JSSC200900696
ark:/67375/WNG-B2WWP28P-4
istex:9FBCD4AC97CD15C315E0C9FD71B2BABE99D5DC93
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Article-1
ObjectType-Feature-2
ISSN:1615-9306
1615-9314
DOI:10.1002/jssc.200900696