Applicability of Ground Granulated Blast-Furnace Slag for Precast Concrete Beams Subjected to Bending Moment
This study evaluates the flexural performance of precast concrete beams using ground granulated blast-furnace slag. A total of four specimens with various replacement ratios of ground granulated blast-furnace slag are cast and tested in flexure. The specimens under four-point loading had a shear spa...
Saved in:
Published in: | Journal of Asian architecture and building engineering Vol. 13; no. 3; pp. 633 - 639 |
---|---|
Main Authors: | , , , |
Format: | Journal Article |
Language: | English |
Published: |
Tokyo
Japan Science and Technology Agency
01-09-2014
|
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This study evaluates the flexural performance of precast concrete beams using ground granulated blast-furnace slag. A total of four specimens with various replacement ratios of ground granulated blast-furnace slag are cast and tested in flexure. The specimens under four-point loading had a shear span-to-depth ratio of 4 and a rectangular section with a width of 200 mm and an effective depth of 300 mm. It can be shown from experimental results that the specimens with ground granulated blast-furnace slag had a similar flexural performance to the specimen with natural aggregates, regardless of the replacement ratios of ground granulated blast-furnace slag. |
---|---|
ISSN: | 1346-7581 1347-2852 |
DOI: | 10.3130/jaabe.13.633 |