Spectral analysis of flow velocity in the contralateral artery during coronary angioplasty: A new method for assessing collateral flow

Objectives. The present study was designed to evaluate a new method for assessing coronary collateral flow and resistance in conscious humans. Background. Earlier pathomorphologic and invasive studies have indicated that collateral vessels are important for salvage of myocardium at risk in acute myo...

Full description

Saved in:
Bibliographic Details
Published in:Journal of the American College of Cardiology Vol. 21; no. 7; pp. 1574 - 1582
Main Authors: Piek, Jan J., Koolen, Jacques J., van Rijn, Alexander C.Metting, Bot, Hans, Hoedemaker, Gerard, David, George K., Dunning, Arend J., Spaan, Jos A.E., Visser, Cees A.
Format: Journal Article
Language:English
Published: New York, NY Elsevier Inc 01-06-1993
Elsevier Science
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objectives. The present study was designed to evaluate a new method for assessing coronary collateral flow and resistance in conscious humans. Background. Earlier pathomorphologic and invasive studies have indicated that collateral vessels are important for salvage of myocardium at risk in acute myocardial infarction. Only a few clinical studies have attempted to express the development of the collateral vascular bed in terms of flow or resistance. Methods. Angiography and flow velocity measurements of the contralateral coronary artery were performed in 38 patients undergoing coronary angioplasty for one-vessel disease. Coronary flow velocity was assessed by zero-crossing frequency analysis in 37 patients and, additionally, by fast Fourier transform spectral analysis in 23. Collateral flow was determined by the decrease of flow velocity after balloon deflation. Mean aortic pressure and coronary wedge pressure were assessed for calculation of collateral vascular resistance. Results. Angiography of the contralateral artery during balloon inflation revealed the presence of collateral vessels in 26 patients (recruitable collateral vessels in 19). Fast Fourier transform spectral analysis demonstrated a significant transient increase of flow velocity during brief coronary occlusion in 15 patients with collateral vessels compared with 8 patients without collateral vessels (4.8 ± 1.3% vs. 23.4 ± 17.2%, p < 0.001). A transient increase in flow velocity (>10%) was less evident by zero-crossing frequency analysis than by fast Fourier transform spectral analysis (sensitivity 8% vs. 87%). The relative resistance of the collateral vascular bed was significantly reduced when collateral vessels were present during coronary occlusion (4.4 ± 3.8 vs. 16.9 ± 4.6, p < 0.001). Furthermore, electrocardiographic signs of ischemia were less present in those 15 patients with collateral vessels (p < 0.05). Conclusions. The beneficial effect of collateral vessels during brief coronary occlusion is exerted by a significant increase of flow in the contralateral artery in combination with a reduced resistance in the collateral vascular bed. The method presented is capable of expressing the development of the collateral vascular bed in terms of flow and resistance.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0735-1097
1558-3597