Defining pulsatility during continuous-flow ventricular assist device support

Continuous-flow ventricular assist devices (CVADs) have gained widespread use as an effective clinical therapy for patients with advanced-stage heart failure. Axial and centrifugal CVADs have been successfully used as bridge-to-transplant and destination therapy. CVADs are smaller, more reliable, an...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of heart and lung transplantation Vol. 32; no. 6; pp. 581 - 587
Main Authors: Soucy, Kevin G., PhD, Koenig, Steven C., PhD, Giridharan, Guruprasad A., PhD, Sobieski, Michael A., RN, CCP, Slaughter, Mark S., MD
Format: Journal Article
Language:English
Published: United States Elsevier Inc 01-06-2013
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Continuous-flow ventricular assist devices (CVADs) have gained widespread use as an effective clinical therapy for patients with advanced-stage heart failure. Axial and centrifugal CVADs have been successfully used as bridge-to-transplant and destination therapy. CVADs are smaller, more reliable, and less complex than the first-generation pulsatile-flow ventricular assist devices. Despite their recent clinical success, arteriovenous malformations, gastrointestinal bleeding, hemorrhagic strokes, aortic valve insufficiency, and valve fusion have been reported in heart failure patients supported by CVADs. It has been hypothesized that diminished arterial pressure and flow pulsatility delivered by CVAD may be a contributing factor to these adverse events. Subsequently, the clinical significance of vascular pulsatility continues to be highly debated. Studies comparing pulsatile-flow and continuous-flow support have presented conflicting findings, largely due to variations in device operation, support duration, and the criteria used to quantify pulsatility. Traditional measurements of pulse pressure and pulsatility index are less effective at quantifying pulsatility for mechanically derived flows, particularly with the growing trend of CVAD speed modulation to achieve various pulsatile flow patterns. Kinetic measurements of energy equivalent pressure and surplus hemodynamic energy can better quantify pulsatile energies, yet technologic and conceptual challenges are impeding their clinical adaption. A review of methods for quantifying vascular pulsatility and their application as a research tool for investigating physiologic responses to CVAD support are presented.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-3
content type line 23
ObjectType-Review-1
ISSN:1053-2498
1557-3117