Comparison of X-Ray Imaging and Computed Tomography Scan in the Evaluation of Knee Trauma
: The aim of the study was to compare the accuracy of X-ray (XR) imaging according to computed tomography (CT) scanning in the diagnosis of knee bone fractures, and in the determination of fracture characteristics, and to identify CT scan indications in patients with knee trauma. : The patients who...
Saved in:
Published in: | Medicina (Kaunas, Lithuania) Vol. 55; no. 10; p. 623 |
---|---|
Main Authors: | , |
Format: | Journal Article |
Language: | English |
Published: |
Switzerland
MDPI
23-09-2019
MDPI AG |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | : The aim of the study was to compare the accuracy of X-ray (XR) imaging according to computed tomography (CT) scanning in the diagnosis of knee bone fractures, and in the determination of fracture characteristics, and to identify CT scan indications in patients with knee trauma.
: The patients who presented to the emergency department (ED) due to knee trauma between January 2017 and December 2018 and who underwent XR imaging and CT scans were included in the study. XR images were reinterpreted by an emergency physician. The official reports, which had been interpreted by a radiologist in the hospital automation system for CT images, were considered valid.
: Five hundred and forty-eight patients were included in the study. Of the patients, 200 (36.5%) had fractures in XR imaging and 208 (38.0%) had fractures in CT scans. Compared to CT scanning, XR imaging was found to have 89% sensitivity, 95% specificity, 92% positive predictive value, and 92% negative predictive value in identifying the fracture. The sensitivity of XR imaging in identifying growth plate fracture, angulation, stepping off, and extension of the fracture into the joint space was determined as 78% and less. According to the kappa value, there was determined a perfect concordance between the XR imaging and CT scans in angulation, stepping off, and extension of the fracture into the joint space. This concordance was moderate in growth plate fractures.
: XR imaging has a low sensitivity in identifying knee fractures. There is a moderate concordance between XR imaging and CT scanning in identifying growth plate fractures. Therefore, CT scanning should be performed in patients whose fracture type and fracture characteristics are not able to be determined exactly with XR imaging in knee injury. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1648-9144 1010-660X 1648-9144 1010-660X |