Stent placement using dual‐channel endoscope for biloma after EUS‐guided hepaticogastrostomy
Highlight Nakamura and colleagues report a case of successful stent placement for biloma through a migrated EUS‐guided hepaticogastrostomy stent, using a dual‐channel endoscope and the hairpin guidewire technique. This method enables biliary drainage as a potential rescue technique for EUS‐guided he...
Saved in:
Published in: | Journal of hepato-biliary-pancreatic sciences Vol. 28; no. 10; pp. e45 - e46 |
---|---|
Main Authors: | , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Japan
Wiley Subscription Services, Inc
01-10-2021
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Highlight
Nakamura and colleagues report a case of successful stent placement for biloma through a migrated EUS‐guided hepaticogastrostomy stent, using a dual‐channel endoscope and the hairpin guidewire technique. This method enables biliary drainage as a potential rescue technique for EUS‐guided hepaticogastrostomy stent obstruction with a long metallic stent in the stomach. |
---|---|