Similar Pharmacokinetics and Pharmacodynamics of Biosimilar SAR342434 Insulin Lispro and Japan‐Approved Humalog Insulin Lispro in Healthy Japanese Subjects

This phase 1 study compared the pharmacokinetic (PK) and glucose pharmacodynamic (PD) characteristics of biosimilar SAR342434 insulin lispro and Japan‐reference Humalog insulin lispro. This was a randomized, double‐blind, 2‐period, crossover study. Thirty‐six healthy Japanese male subjects underwent...

Full description

Saved in:
Bibliographic Details
Published in:Clinical pharmacology in drug development Vol. 11; no. 6; pp. 754 - 760
Main Authors: Shiramoto, Masanari, Yoshihara, Tatsuya, Schmider, Wolfgang, Takahashi, Yoshinori, Nowotny, Irene, Kajiwara, Miyuki, Muto, Hideya
Format: Journal Article
Language:English
Published: United States Wiley Subscription Services, Inc 01-06-2022
John Wiley and Sons Inc
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This phase 1 study compared the pharmacokinetic (PK) and glucose pharmacodynamic (PD) characteristics of biosimilar SAR342434 insulin lispro and Japan‐reference Humalog insulin lispro. This was a randomized, double‐blind, 2‐period, crossover study. Thirty‐six healthy Japanese male subjects underwent a 10‐hour euglycemic clamp following a single subcutaneous 0.3‐U/kg dose of SAR342434 or Humalog. Insulin lispro concentration and blood glucose were measured, and the glucose infusion rate (GIR) was adjusted to maintain the target blood glucose level. Primary PK end points were maximum plasma insulin lispro concentration and area under the plasma insulin concentration–time curve (AUC) from time 0 to the last quantifiable concentration. Primary PD end points were area under the GIR–time curve from time 0 to 10 hours and maximum GIR. PK exposure (maximum plasma concentration and AUC from time 0 to the last quantifiable concentration) and PD activity (GIR‐AUC from time 0 to 10 hours and maximum GIR) were similar between treatments. Geometric mean ratios were close to 1, and the corresponding 90% and 95%CIs (PK and PD activity, respectively) were within the 0.80 to 1.25 equivalence range. SAR342434 and Humalog were well tolerated. In healthy Japanese males, SAR342434 and Humalog showed similar PK exposure profiles and PD potency, in support of SAR342434 use as a biosimilar product.
Bibliography:Current address: Kashiihara Hospital, Fukuoka, Japan
Current address: Novartis Japan, Tokyo, Japan
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
ObjectType-News-3
content type line 23
ISSN:2160-763X
2160-7648
DOI:10.1002/cpdd.1068