Multicenter study of device-associated infection rates in hospitals of Mongolia: Findings of the International Nosocomial Infection Control Consortium (INICC)
Background To report the results of the International Nosocomial Infection Control Consortium (INICC) multicenter study conducted in Mongolia from September 2013-March 2015. Methods A device-associated health care–associated infection prospective surveillance study in 3 adult intensive care units (I...
Saved in:
Published in: | American journal of infection control Vol. 44; no. 3; pp. 327 - 331 |
---|---|
Main Authors: | , , , , , , , , , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
United States
Elsevier Inc
01-03-2016
Mosby-Year Book, Inc |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Background To report the results of the International Nosocomial Infection Control Consortium (INICC) multicenter study conducted in Mongolia from September 2013-March 2015. Methods A device-associated health care–associated infection prospective surveillance study in 3 adult intensive care units (ICUs) from 3 hospitals using the U.S. Centers for Disease Control and Prevention (CDC) and National Healthcare Safety Network (NHSN) definitions and INICC methods. Results We documented 467 ICU patients for 2,133 bed days. The central line–associated bloodstream infection (CLABSI) rate was 19.7 per 1,000 central line days, the ventilator-associated pneumonia (VAP) rate was 43.7 per 1,000 mechanical ventilator days, and the catheter-associated urinary tract infection (CAUTI) rate was 15.7 per 1,000 urinary catheter days; all of the rates are higher than the INICC rates (CLABSI: 4.9; VAP: 16.5; and CAUTI: 5.3) and CDC-NHSN rates (CLABSI: 0.8; VAP: 1.1; and CAUTI: 1.3). Device use ratios were also higher than the CDC-NHSN and INICC ratios, except for the mechanical ventilator device use ratio, which was lower than the INICC ratio. Resistance of Staphylococcus aureus to oxacillin was 100%. Extra length of stay was 15.1 days for patients with CLABSI, 7.8 days for patients with VAP, and 8.2 days for patients with CAUTI. Extra crude mortality in the ICUs was 18.6% for CLABSI, 17.1% for VAP, and 5.1% for CAUTI. Conclusion Device-associated health care–associated infection rates and most device use ratios in our Mongolian hospitals' ICUs are higher than the CDC-NSHN and INICC rates. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0196-6553 1527-3296 |
DOI: | 10.1016/j.ajic.2015.10.010 |