Comparative evaluation of tests for detection of parvovirus B19 IgG and IgM

The aim of this study was to evaluate enzyme immunoassays (EIA) (Euroimmun, Lübeck, Germany) and chemiluminiscent immunoassays (CLIA) (Diasorin, Saluggia, Italy) in their application to detect B19V‐IgM and ‐IgG. For this purpose, one hundred and ninety samples were studied. Of them, 101 came from re...

Full description

Saved in:
Bibliographic Details
Published in:APMIS : acta pathologica, microbiologica et immunologica Scandinavica Vol. 122; no. 3; pp. 223 - 229
Main Authors: de Ory, Fernando, Minguito, Teodora, Echevarría, Juan Emilio, del Mar Mosquera, María, Fuertes, Antonio
Format: Journal Article
Language:English
Published: Denmark Blackwell Publishing Ltd 01-03-2014
Wiley Subscription Services, Inc
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The aim of this study was to evaluate enzyme immunoassays (EIA) (Euroimmun, Lübeck, Germany) and chemiluminiscent immunoassays (CLIA) (Diasorin, Saluggia, Italy) in their application to detect B19V‐IgM and ‐IgG. For this purpose, one hundred and ninety samples were studied. Of them, 101 came from recent infection cases (B19V‐specific IgM (86) and/or PCR (87), 42 from past infections, 18 from non‐infected, and 29 from other viral recent infections (Epstein‐Barr virus, measles, and rubella). Samples were characterized by capture (for IgM), or indirect (for IgG) EIA (Biotrin, Dublin, Ireland); indeterminate samples were classified by indirect immunofluorescence (IIF) (Biotrin). All the samples were used for testing IgM assays, and all but the cases from other viral infections were used for IgG tests. For IgM, CLIA, and EIA identified 76 and 62 of 86 IgM positives, respectively (sensitivity 88.4% and 72.1%). Considering B19V IgM negative samples, negative result was obtained in 95 and 92 of 104, being the specificity values of CLIA and EIA 91.3% and 88.5%, respectively. For IgG, CLIA and EIA identified correctly 114 and 115 of the 122 positive samples (sensitivity 93.4% and 94.3%, respectively), and 39 and 36 of 39 negative samples (specificity 100% and 92.3%). As conclusion, CLIA methods can be used in clinical laboratories as adequate alternatives to the well‐established Biotrin EIAs.
Bibliography:ArticleID:APM12127
ark:/67375/WNG-BHZRJPMT-X
istex:8C783B1E231FE65813C841B8A14D4525E31E45CE
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0903-4641
1600-0463
DOI:10.1111/apm.12127