Anatomical Breast Implant Assessment Using Ultrasound: A Case Series from the International Breast Implant Check Clinic

Breast augmentation with anatomic implants can achieve a natural look, but over time, implant-related complications can occur. This includes a risk of potential rotation, which can cause a change in breast shape. Reported rates of rotation vary widely (0%-42%). Implant rotation is often detected by...

Full description

Saved in:
Bibliographic Details
Published in:Plastic and reconstructive surgery. Global open Vol. 11; no. 12; p. e5469
Main Authors: Jaeger, Marie, Randquist, Charles, Gahm, Jessica
Format: Journal Article
Language:English
Published: United States Lippincott Williams & Wilkins 01-12-2023
Wolters Kluwer
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Breast augmentation with anatomic implants can achieve a natural look, but over time, implant-related complications can occur. This includes a risk of potential rotation, which can cause a change in breast shape. Reported rates of rotation vary widely (0%-42%). Implant rotation is often detected by physical examination only or as a perioperative finding. Change in breast shape after augmentation requires clinical evaluation. In-office ultrasound allows for detailed assessment of implants for rotation and other complications. Women with anatomical breast implants seeking follow-up at the International Breast Implant Check Clinic in Stockholm, Sweden, from April 2020 to July 2022 were included in the study. Using a standardized protocol, subjective symptoms were recorded, and a physical examination followed by an ultrasound assessment was performed by a single board-certified plastic surgeon (M.J.) trained in implant assessment via ultrasound. Rotation was defined as an implant rotated past 30 degrees off the breast midline at 6 o'clock. The study included 308 women (mean age 40.1, range 20-78) with bilateral anatomical implants. Overall, 40 women (13.0%) reported a change in breast shape; 35 had one or more implant-related complications, including five with rotation on ultrasound. Of the 308 women, 11 (3.6%) had rotations upon physical examination, and an additional 10 cases were identified using ultrasound. Rotation is a potential complication of anatomical breast implants. However, in this study, change in breast shape was more commonly caused by other implant-related complications. Ultrasound is a valuable tool in evaluating causes of change in breast shape.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2169-7574
2169-7574
DOI:10.1097/GOX.0000000000005469