Comparison of PMTs from three different manufacturers for the CMS-HF forward calorimeter

The builders of the CMS forward hadron calorimeter established a set of specifications for readout PMTs that reflected the physics goals and mechanical needs of the CMS experiment. Three manufacturers, Hamamatsu, Photonis (Philips), and Electron Tubes (EMI), provided candidate PMTs based on these in...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on nuclear science Vol. 51; no. 4; pp. 1909 - 1915
Main Authors: Akgun, U., Anderson, E.W., Ayan, A.S., Gulmez, E., Miller, M., Onel, Y., Schmidt, I., Winn, D.
Format: Journal Article
Language:English
Published: New York IEEE 01-08-2004
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The builders of the CMS forward hadron calorimeter established a set of specifications for readout PMTs that reflected the physics goals and mechanical needs of the CMS experiment. Three manufacturers, Hamamatsu, Photonis (Philips), and Electron Tubes (EMI), provided candidate PMTs based on these initial requirements. Timing, gain, dark current properties, and single photoelectron spectra of these candidate PMTs were measured. Results show that Hamamatsu PMTs (R7525HA) conform best to the specifications of the Hadron-Forward (HF) Calorimeter.