Radiofrequency ablation of hepatocellular carcinoma guided by real-time physics-based ablation simulation: a prospective study

To assess the safety and efficacy of radiofrequency ablation (RFA) guidance software that incorporated patient-specific physics-based simulation of each ablation volume. Patients referred for curative ablation of hepatocellular carcinoma (HCC) of 2-5 cm diameter were prospectively enrolled. RFA was...

Full description

Saved in:
Bibliographic Details
Published in:International journal of hyperthermia Vol. 41; no. 1; p. 2331704
Main Authors: Hoffer, Eric K, Drinane, Mary C, Bhatnagar, Vikrant, Mehta, Riya, Munger, David P, Borsic, Andrea
Format: Journal Article
Language:English
Published: England Taylor & Francis Group 2024
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To assess the safety and efficacy of radiofrequency ablation (RFA) guidance software that incorporated patient-specific physics-based simulation of each ablation volume. Patients referred for curative ablation of hepatocellular carcinoma (HCC) of 2-5 cm diameter were prospectively enrolled. RFA was performed under general anesthesia. Procedure planning and intraprocedural modifications were guided by computer simulation of each ablation. The segmented target (tumor with 5 mm margin) was registered to and superimposed on subsequent 3D multiplanar images. The applied RF energy was used to calculate a simulated ablation volume which was displayed relative to the electrode and segmented target, to depict any untreated target tissue. After each additional ablation, the software updated the accumulated simulated ablation volume in relation to the target. The primary endpoints were technical efficacy and rate of local tumor progression (LTP). Sixty-eight tumors were ablated during 57 procedures in 52 patients (68.3 ± 9.2 years old, 78.8% male); 15 (26.3%) had multiple lesions and 23 (39.1%) had prior HCC treatment. The mean tumor diameter was 2.73 (±0.64) cm. The intraprocedural simulation directed additional overlapping ablations in 75.9% of tumors. Technical success and efficacy were 100% at 3-month contrast enhanced CT or MRI follow-up after the single treatment session. Cumulative incidence function estimates for 1- and 2-year LTP were 3.9% and 20.2%, respectively. This prospective study found computer-assisted guidance that simulated each ablation was both safe and efficacious. The low rate of LTP was similar to studies that employed stereotactic guidance and ablation confirmation, without requiring a second contrast enhanced study.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0265-6736
1464-5157
DOI:10.1080/02656736.2024.2331704