A comparison of clinical and angiographic outcomes after Excel bioabsorbable polymer versus Firebird durable polymer rapamycin-eluting stent for the treatment of coronary artery disease in a "real world" setting: six-month follow-up results

Background Several clinical trials have shown that rapamycin-eluting stents significantly reduce the risk of restenosis after percutaneous coronary intervention (PCI). The Firebird stent and the Excel stent (coated with bioabsorbable polymer) are two different types of rapamycin-eluUng stents made i...

Full description

Saved in:
Bibliographic Details
Published in:Chinese medical journal Vol. 120; no. 7; pp. 574 - 577
Main Authors: Liu, Hai-bo, Xu, Bo, Qiao, Shu-bin, Yang, Yue-jin, Ma, Wei-hua, Qin, Xue-wen, Yao, Min, Wu, Yong-jian, Yuan, Jin-qing, Chen, Jue, You, Shi-jie, Dai, Jun, Xia, Ran, Li, Jian-jun, Chen, Ji-lin, Gao, Run-lin
Format: Journal Article
Language:English
Published: China Department of Cardiology, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100037, China 05-04-2007
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background Several clinical trials have shown that rapamycin-eluting stents significantly reduce the risk of restenosis after percutaneous coronary intervention (PCI). The Firebird stent and the Excel stent (coated with bioabsorbable polymer) are two different types of rapamycin-eluUng stents made in China, both have been recently approved for clinical use in China by State Food and Drug Administration. However, it is unclear whether there are differences in safety and efficacy between the two types of stents in daily practice. Methods In the month of June 2006, a total of 190 consecutive patients were treated exclusively with Firebird stents (n=93, Firebird group) or Excel stents (n=97, Excel group) in our center and were included in this study. The frequency of major adverse cardiac events (MACE, a composite of death, myocardial infarction or target lesion revascularization), binary restenosis, and late lumen loss and stent thrombosis dudng a six-month follow-up period were compared between the two groups. Results Patient and lesion characteristics were comparable between the groups. Major adverse cardiac event rates were low in hospital and at 6 months (2.1% in the Excel group and 0% in the Firebird group, P〉 0.05). The 6-month angiographic in-stent restenosis rate was 0% in both groups, with an associated late loss of (0.15 ± 0.21) mm versus (0.14 ± 0.20) mm (P=0.858) and the in-segment restenosis rate was also 0% for the Excel group and the Firebird group. There was no definite stent thrombosis identified in either group during the six-month follow-up period and only one patient in the Excel group had probable stent thrombosis in hospital. Conclusions Results from this mid-term, single-center study showed that both of the Firebird and the Excel rapamycin eluUng stent had similar effects on reducing the incidence of MACE and the risk of restenosis (both in-stent and in-segment binary restenosis) after PCI in daily practice.
Bibliography:percutaneous coronary intervention
comparative study
drug-eluting stent
bioabsorbable polymer
percutaneous coronary intervention; drug-eluting stent; bioabsorbable polymer; comparative study
11-2154/R
R541.4
R654.2
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0366-6999
2542-5641
DOI:10.1097/00029330-200704010-00009