Energy transfer procession in an air source heat pump unit during defrosting

•Energy transfer procession in an ASHP unit during defrosting was explored.•Effect of metal energy storage on defrosting was proposed and calculated.•Metal energy storage effect was changed from positive (0.33%) to negative (−2.18%).•Defrosting efficiency was improved about 6.08%, from 42.26% to 48....

Full description

Saved in:
Bibliographic Details
Published in:Applied energy Vol. 204; pp. 679 - 689
Main Authors: Song, Mengjie, Xu, Xiangguo, Mao, Ning, Deng, Shiming, Xu, Yingjie
Format: Journal Article
Language:English
Published: Elsevier Ltd 15-10-2017
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•Energy transfer procession in an ASHP unit during defrosting was explored.•Effect of metal energy storage on defrosting was proposed and calculated.•Metal energy storage effect was changed from positive (0.33%) to negative (−2.18%).•Defrosting efficiency was improved about 6.08%, from 42.26% to 48.34%.•Contributions of this study can guide the design optimization of two ASHP’s coils. Air source heat pump units have found their wide applications in recent decades due to their high efficiency and low environmental pollution. To solve their undesired frosting problem, reverse cycle defrosting is always employed. As a transient and nonlinear heat and mass transfer procession, defrosting performance directly affects the occupants’ thermal comfort. During defrosting, the metal energy storage values of indoor and outdoor coils are varied as their temperature fluctuations. It is therefore necessary to investigate the energy transfer procession in an air source heat pump unit and the effect of metal energy storage during defrosting. However, scarce of attentions were paid to this fundamental problem. In this study, two experimental cases with two-working-circuit and three-working-circuit outdoor coils were conducted basing on frost evenly accumulated on their surfaces. After four types of energy supply and five types of energy consumption during defrosting were calculated, a qualitative and quantitative evaluation on the metal energy storage effect was then given. As concluded, after the outdoor coil enlarged 50%, the metal energy storage effect can be changed from positive (0.33%) to negative (−2.18%). The percentages of energy consumed on melting frost and vaporizing retained water were both increased. Defrosting efficiency was improved about 6.08%, from 42.26% to 48.34%. Contributions of this study can effectively guide the design optimization of indoor and outdoor coils and promote the energy saving for air source heat pump units.
ISSN:0306-2619
1872-9118
DOI:10.1016/j.apenergy.2017.07.063