Sagittal and vertical load-deflection and permanent deformation of transpalatal arches connected with palatal implants: An in-vitro study

Introduction: The purposes of this laboratory investigation were to (1) measure the sagittal and vertical deflection of loaded transpalatal arches (TPAs) connected to a palatal implant, (2) measure the extent of permanent deformation of the connecting TPA in the sagittal and vertical directions, (3)...

Full description

Saved in:
Bibliographic Details
Published in:American journal of orthodontics and dentofacial orthopedics Vol. 131; no. 6; pp. 742 - 752
Main Authors: Crismani, Adriano G, C̆elar, Aleš G, Burstone, Charles J, Bernhart, Thomas G, Bantleon, Hans-Peter, Mittlboeck, Martina
Format: Journal Article
Language:English
Published: United States Mosby, Inc 01-06-2007
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Introduction: The purposes of this laboratory investigation were to (1) measure the sagittal and vertical deflection of loaded transpalatal arches (TPAs) connected to a palatal implant, (2) measure the extent of permanent deformation of the connecting TPA in the sagittal and vertical directions, (3) test various wire dimensions in terms of deflection behavior, and (4) evaluate soldering vs laser welding vs adhesive bonding of TPAs in terms of load deflection behavior. Methods: Stainless steel wires of 6 dimensions were tested: 0.8 × 0.8, 0.9, 1, 1.1, 1.2, and 1.2 × 1.2 mm. For each dimension, 10 specimens were soldered to the palatal implant abutment, 10 were laser welded, and 10 were adhesively bonded to the implant abutment (total, 180 specimens). The measuring device applied increments of force of 50 cN, from 0 to 500 cN. Then the specimens were unloaded. The values were statistically described and analyzed with ANOVA and Wilcoxon rank sum tests. Results and Conclusions: Absolute orthodontic anchorage without deformation of TPAs was not observed with the wire dimensions tested. To prevent loss of anchorage greater than 370 μm (sagittal deflection of 1.2 × 1.2 mm adhesively bonded TPA at 500 cN force level), wires thicker than 1.2 × 1.2 mm or cast anchorage elements must be considered for clinical practice. However, larger cross sections might cause more patient discomfort, and laboratory procedures increase costs.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0889-5406
1097-6752
DOI:10.1016/j.ajodo.2005.06.035