Transcatheter Left Atrial Appendage Closure Using Intracardiac Echocardiographic Guidance From the Left Atrium
Abstract Background Most commonly, left atrial appendage (LAA) occlusion procedures are performed using transesophageal echocardiography (TEE) guidance and general anaesthesia. Intracardiac echocardiography (ICE) offers potential advantages over TEE, however, ICE-guided LAA occlusion experience is l...
Saved in:
Published in: | Canadian journal of cardiology Vol. 31; no. 12; pp. 1497.e7 - 1497.e14 |
---|---|
Main Authors: | , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
England
Elsevier Inc
01-12-2015
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Abstract Background Most commonly, left atrial appendage (LAA) occlusion procedures are performed using transesophageal echocardiography (TEE) guidance and general anaesthesia. Intracardiac echocardiography (ICE) offers potential advantages over TEE, however, ICE-guided LAA occlusion experience is limited and has been typically performed from a right-sided location where LAA visualization might be suboptimal. We sought to evaluate the efficacy and safety of percutaneous LAA occlusion using ICE guidance performed from the left atrium. Methods Thirty-seven patients with atrial fibrillation, significant risk for stroke, and long-term contraindication to anticoagulation underwent LAA closure with the Amplatzer Cardiac Plug (St Jude Medical, Inc, St Paul, MN) with mild sedation and ICE guidance. The ICE catheter was introduced in the left atrium through a second transseptal puncture. Patients underwent preprocedural TEE to rule out thrombus and 3-month follow-up TEE to assess occlusion grade. Patient characteristics, procedural data, effectiveness of ICE imaging, quality of occlusion, and complications were prospectively recorded. Results Procedural success was achieved in 36 of 37 patients (97%). Closure was complete or near complete (grade ≥3 according to ICE and angiography) in all cases where the device was released. In all cases, ICE imaging yielded good LAA and surrounding structure visualization and adequate procedural guidance. Three major procedural or in-hospital complications occurred. Median length of stay was 1 day. Follow-up TEE documented the absence of any residual peri-device leak in all but 1 (29 of 30) case. Conclusion Initial experience suggests LAA occlusion with the Amplatzer Cardiac Plug using ICE guidance from the left atrium is feasible, reproducible, and safe. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0828-282X 1916-7075 |
DOI: | 10.1016/j.cjca.2015.04.031 |