A cyanoacrylate and silastic patch to reduce the risk of opening of the tumor: Technical note

Abstract Background Wide surgery is the main factor influencing survival in muscular skeletal tumor. Sometimes the margin can be very thin and the contamination risk can be very high because of manipulation of the mass. Materials and methods A patch of cyanoacrylate and a silastic mesh are applied o...

Full description

Saved in:
Bibliographic Details
Published in:European journal of surgical oncology Vol. 39; no. 1; pp. 44 - 45
Main Authors: Zoccali, C, Covello, R, Di Francesco, A, Zoccali, G
Format: Journal Article
Language:English
Published: England Elsevier Ltd 01-01-2013
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Background Wide surgery is the main factor influencing survival in muscular skeletal tumor. Sometimes the margin can be very thin and the contamination risk can be very high because of manipulation of the mass. Materials and methods A patch of cyanoacrylate and a silastic mesh are applied on tumor surface. In order to demonstrate the tumor sealing an histologic exam was performed. Discussion The application of protective patch can decrease the risk of accidental tumor rupture and neoplastic cells spreading.
Bibliography:ObjectType-Case Study-3
SourceType-Scholarly Journals-1
content type line 23
ObjectType-Feature-5
ObjectType-Technical Report-1
ObjectType-Report-2
ObjectType-Article-4
ISSN:0748-7983
1532-2157
DOI:10.1016/j.ejso.2012.08.025