Intra-cavity Photodynamic Therapy for malignant tumors of the paranasal sinuses: An in vivo light dosimetry study

•Sinonasal PDT dosimetry demonstrated variations in fluence and fluence rate.•Sinonasal-cavity fluence and fluence rate variations are temporal and spatial.•In the majority of patients the measured fluence was below the pre-aimed 20 J cm−2.•The current intra-cavity dosimetry approach is not reproduc...

Full description

Saved in:
Bibliographic Details
Published in:Photodiagnosis and photodynamic therapy Vol. 32; p. 101972
Main Authors: van Doeveren, T.E.M., van Veen, R.L.P., van den Boom, F., Tan, I.B., Schreuder, W.H., Karakullukçu, M.B.
Format: Journal Article
Language:English
Published: Netherlands Elsevier B.V 01-12-2020
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•Sinonasal PDT dosimetry demonstrated variations in fluence and fluence rate.•Sinonasal-cavity fluence and fluence rate variations are temporal and spatial.•In the majority of patients the measured fluence was below the pre-aimed 20 J cm−2.•The current intra-cavity dosimetry approach is not reproducible or standardized.•There is a need for in vivo dosimetry and dosimetry planning during sinonasal PDT. Photodynamic therapy (PDT) is a promising treatment option for recurrent sinonasal malignancies. However, light administration in this area is challenging given the complex geometry, varying tissue optical properties and difficult accessibility. The goal of this study was to estimate the temporal and spatial variation in fluence and fluence rate during sinonasal mTHPC-mediated PDT. It was investigated whether the predetermined aim to illuminate with a fluence of 20 J⋅cm−2 and fluence rate of 100 mW⋅cm−2 was achieved. In eleven patients the fluence and fluence rates were measured using in vivo light dosimetry at the target location during real-time sinonasal PDT. There was a variance in sinonasal target location and type of light diffuser used. In four patients two isotropic detectors were used within the same cavity. All measurements showed major fluence rate fluctuations within each single isotropic detector probe over time, as well as between probes within the same cavity. The largest fluence rate range measured was 328 mW⋅cm−2. Only one probe showed a mean fluence rate of ∼100 mW⋅cm−2. Taken all probes together, a fluence rate above 80 mW⋅cm−2 was measured in 31 % of the total light exposure; in 22 % it was less than 20 mW⋅cm−2. Thirty-three percent showed a fluence of at least 20 J⋅cm−2. The current dosimetry approach for sinonasal intra-cavity PDT shows major temporal and spatial variations in fluence rate and a large variance in light exposure time. The results emphasize the need for improvement of in vivo light dosimetry and dosimetry planning.
ISSN:1572-1000
1873-1597
DOI:10.1016/j.pdpdt.2020.101972