Evaluation of the performance of GeneSoC®, a novel rapid real-time PCR system, to detect Staphylococcus aureus and methicillin resistance in blood cultures

Staphylococcus aureus bacteremia results in substantial mortality. Rapid identification and the determination of methicillin susceptibility are crucial for immediate treatment with appropriate antibiotics. In the present study, we aimed to evaluate the basic assay performance of GeneSoC®, a novel ra...

Full description

Saved in:
Bibliographic Details
Published in:Journal of infection and chemotherapy : official journal of the Japan Society of Chemotherapy Vol. 29; no. 7; pp. 718 - 721
Main Authors: Chiba, Mikiko, Aoyagi, Tetsuji, Yoshida, Makiko, Katsumi, Makoto, Fujimaki, Shin-ichi, Ishii, Yoshikazu, Tateda, Kazuhiro, Kaku, Mitsuo
Format: Journal Article
Language:English
Published: Netherlands Elsevier Ltd 01-07-2023
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Staphylococcus aureus bacteremia results in substantial mortality. Rapid identification and the determination of methicillin susceptibility are crucial for immediate treatment with appropriate antibiotics. In the present study, we aimed to evaluate the basic assay performance of GeneSoC®, a novel rapid quantitative polymerase chain reaction (qPCR) method, for the detection of methicillin-susceptible (MS) or -resistant (MR) S. aureus in blood culture (BC) bottles. qPCR pimers and probes were desinged for femA and mecA genes to diagnose S. aureus and its methicilline-resistance status. GeneSoC® system can detect target genes within 12 min per sample using microfludic thermal cycling. A total of 100 BC-positive samples, showing clusters of gram-positive cocci using microscopy, were tested. The analytical sensitivity was demonstrated for the target sequence of femA and mecA genes at 10 copies/μL, respectively. The detection limit of the MRSA bacterial burden using this system was 104 and 103 CFU/mL for femA and mecA, respectively. Compared with culture-based identification and susceptibility testing, the sensitivity and specificity for the detection of femA (+)/mecA (+) MRSA using GeneSoC® were 90.9 and 98.9%, respectively, whereas the sensitivity and specificity for detection of femA (+)/mecA (-) MSSA were 96.2% and 97.3%, respectively. In conclusion, although this was a small sample and pilot study, the GeneSoC® system is beneficial for rapid, reliable, and highly sensitive real-time testing of MRSA and MSSA in BC bottles.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1341-321X
1437-7780
DOI:10.1016/j.jiac.2023.03.006