Cavum septi pellucidi (CSP) ratio: a marker for partial agenesis of the fetal corpus callosum

ABSTRACT Objective While complete agenesis of the corpus callosum is often suspected on fetal ultrasound due to absence of the cavum septi pellucidi (CSP), suspicion of partial agenesis of the corpus callosum (pACC) is a challenge since the CSP is almost always present. The aim of this study was to...

Full description

Saved in:
Bibliographic Details
Published in:Ultrasound in obstetrics & gynecology Vol. 50; no. 3; pp. 336 - 341
Main Authors: Karl, K., Esser, T., Heling, K. S., Chaoui, R.
Format: Journal Article
Language:English
Published: Chichester, UK John Wiley & Sons, Ltd 01-09-2017
Wiley Subscription Services, Inc
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:ABSTRACT Objective While complete agenesis of the corpus callosum is often suspected on fetal ultrasound due to absence of the cavum septi pellucidi (CSP), suspicion of partial agenesis of the corpus callosum (pACC) is a challenge since the CSP is almost always present. The aim of this study was to measure the length and width of the CSP and calculate the length‐to‐width ratio (CSP ratio), and compare these between fetuses with pACC and normal fetuses. Methods In this retrospective case–control study, the length and width of the CSP were measured in the axial plane of the fetal head, and the CSP length‐to‐width ratio calculated, in 323 normal fetuses and in 20 fetuses with pACC between 20 and 34 weeks' gestation. From the normal population we constructed reference ranges in relation to biparietal diameter (BPD). For all fetuses we calculated Z‐scores for the CSP ratio. Results In the normal population, the length and width of the CSP increased with increasing BPD, while the CSP ratio decreased. The CSP was short (< 5th centile) in 85% (17/20) of fetuses with pACC and wide (> 95th centile) in 65% (13/20). The CSP ratio was small (< 5th centile) in 95% (19/20) of pACC fetuses, with 16/20 (80%) having a ratio below an empirical cut‐off of 1.5. Analysis of Z‐scores showed that fetuses with pACC had a significantly smaller CSP ratio (P < 0.0001) compared with the normal population. Conclusions Fetuses with a normal‐sized corpus callosum have a rectangular‐shaped CSP, with a CSP ratio > 1.5 in the second half of gestation. Most fetuses with pACC have an abnormally shaped, wide and short CSP, with a decreased CSP ratio. This simple ratio has the potential to identify fetuses at high risk for pACC. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0960-7692
1469-0705
DOI:10.1002/uog.17409