Bedside Ultrasound can Safely Eliminate the Need for Chest Radiographs after Central Venous Catheter Placement: CVC Sono in the Surgical ICU (SICU)

Background Real-time ultrasound guidance of central venous catheter (CVC)/peripherally inserted central catheter (PICC) insertion improves safety and efficacy. We hypothesized that a more robust ultrasound surveillance technique incorporating thoracic, vascular, and cardiac views—the CVC sono—would...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of surgical research Vol. 163; no. 1; pp. 155 - 161
Main Authors: Matsushima, Kazuhide, M.D, Frankel, Heidi L., M.D., F.A.C.S., F.C.C.M
Format: Journal Article Conference Proceeding
Language:English
Published: New York, NY Elsevier 01-09-2010
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background Real-time ultrasound guidance of central venous catheter (CVC)/peripherally inserted central catheter (PICC) insertion improves safety and efficacy. We hypothesized that a more robust ultrasound surveillance technique incorporating thoracic, vascular, and cardiac views—the CVC sono—would avoid the need for chest radiography to realize cost and efficiency gains. Methods We conducted a prospective data collection in a high-volume, urban, academic SICU. A single surgical intensivist, blinded to the results of chest radiography, performed all CVC sonos post-insertion. Catheter malposition was defined as location extrinsic to the superior vena cava and determined by a board-certified radiologist on chest radiography. CVC sono consisted of (1) mechanical complications screen (hemo-, pneumothorax), (2) intravenous tip screen, (3) intracardiac tip screen. The result of CVC sono was compared with chest radiography. Results CVC sono evaluated 83 catheters (42 CVCs and 41 PICCs) and was considered technically adequate in 59 (71%). Incomplete studies were significantly more common in those with chest tubes ( P = 0.02), but not in those with cervical collars ( P = 0.07), an open abdomen ( P = 0.28), or BMI > 40 ( P = 0.33). Mean CVC sono time was 10.8 min, compared with chest radiography of 75.3 min ( P < 0.001). No hemo-pneumothoraces developed. Presence of multiple indwelling central catheters (>1 CVC) trended for inaccurate CVC sono for catheter malposition (accuracy: 79% versus 93%, P = 0.11). Conclusion A novel ultrasound technique, CVC sono eliminated the need for chest radiography in most patients after CVC/PICC insertion, saving time and money. Those with multiple indwelling central catheters may still require post-insertion conventional chest radiography.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:0022-4804
1095-8673
DOI:10.1016/j.jss.2010.04.020