Implementation of a triple Gaussian beam model with subdivision and redefinition against density heterogeneities in treatment planning for scanned carbon-ion radiotherapy
Challenging issues in treatment planning for scanned carbon-ion (C-ion) therapy are (i) accurate calculation of dose distribution, including the contribution of large angle-scattered fragments, (ii) reduction in the memory space required to store the dose kernel of individual pencil beams and (iii) ...
Saved in:
Published in: | Physics in medicine & biology Vol. 59; no. 18; p. 5361 |
---|---|
Main Authors: | , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
England
21-09-2014
|
Subjects: | |
Online Access: | Get more information |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Challenging issues in treatment planning for scanned carbon-ion (C-ion) therapy are (i) accurate calculation of dose distribution, including the contribution of large angle-scattered fragments, (ii) reduction in the memory space required to store the dose kernel of individual pencil beams and (iii) shortening of computation time for dose optimization and calculation. To calculate the dose contribution from fragments, we modeled the transverse dose profile of the scanned C-ion beam with the superposition of three Gaussian distributions. The development of pencil beams belonging to the first Gaussian component was calculated analytically based on the Fermi-Eyges theory, while those belonging to the second and third components were transported empirically using the measured beam widths in a water phantom. To reduce the memory space for the kernels, we stored doses only in the regions of interest considered in the dose optimization. For the final dose calculation within the patient's whole body, we applied a pencil beam redefinition algorithm. With these techniques, the triple Gaussian beam model can be applied not only to final dose calculation but also to dose optimization in treatment planning for scanned C-ion therapy. To verify the model, we made treatment plans for a homogeneous water phantom and a heterogeneous head phantom. The planned doses agreed with the measurements within ±2% of the target dose in both phantoms, except for the doses at the periphery of the target with a high dose gradient. To estimate the memory space and computation time reduction with these techniques, we made a treatment plan for a bone sarcoma case with a target volume of 1.94 l. The memory space for the kernel and the computation time for final dose calculation were reduced to 1/22 and 1/100 of those without the techniques, respectively. Computation with the triple Gaussian beam model using the proposed techniques is rapid, accurate and applicable to dose optimization and calculation in treatment planning for scanned C-ion therapy. |
---|---|
ISSN: | 1361-6560 |
DOI: | 10.1088/0031-9155/59/18/5361 |