Extracorporeal membrane oxygenator support for human lung transplantation

Extracorporeal membrane oxygenator (ECMO) support was provided for a 19-year-old boy undergoing right lung transplantation. Perfusion was begun several hours prior to transplant, to correct profound hypercapnia. After the operation, ECMO was required because of inadequate gas exchange by the transpl...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of thoracic and cardiovascular surgery Vol. 76; no. 1; p. 28
Main Authors: Nelems, J M, Duffin, J, Glynn, F X, Brebner, J, Scott, A A, Cooper, J D
Format: Journal Article
Language:English
Published: United States 01-07-1978
Subjects:
Online Access:Get more information
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Extracorporeal membrane oxygenator (ECMO) support was provided for a 19-year-old boy undergoing right lung transplantation. Perfusion was begun several hours prior to transplant, to correct profound hypercapnia. After the operation, ECMO was required because of inadequate gas exchange by the transplanted lung. Perfusion was continued for a total of 96 hours. During this time, the temporary malfunction of the transplanted lung owing to the reimplantation response reversed, and the patient was successfully removed from the oxygenator and subsequently weaned from the ventilator. He died on the eighteenth postoperative day of bronchial dehiscence. ECMO support appears to be a feasible means of supporting patients during lung transplantation and during the period of reversible lung malfunction that may occur in the early postoperative period.
ISSN:0022-5223
DOI:10.1016/s0022-5223(19)40929-x