The biodegradable self‐reinforced poly‐dl‐lactic acid spiral stent compared with a suprapubic catheter in the treatment of post‐operative urinary retention after visual laser ablation of the prostate

Objective  To evaluate the efficacy and safety of a biodegradable self‐reinforced poly‐dl‐lactic acid (SR‐PLA) spiral stent compared with a suprapubic catheter after visual laser ablation of the prostate (VLAP) in a randomized study. Patients and methods  The study comprised 45 patients (mean age 67...

Full description

Saved in:
Bibliographic Details
Published in:British Journal of Urology Vol. 80; no. 3; pp. 439 - 443
Main Authors: PÉTAS, A., TALJA, M., TAMMELA, T.L.J., TAARI, K., VÄLIMAA, T., TÖRMÄLÄ, P.
Format: Journal Article
Language:English
Published: Oxford, UK Blackwell Science Ltd 01-09-1997
Blackwell
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objective  To evaluate the efficacy and safety of a biodegradable self‐reinforced poly‐dl‐lactic acid (SR‐PLA) spiral stent compared with a suprapubic catheter after visual laser ablation of the prostate (VLAP) in a randomized study. Patients and methods  The study comprised 45 patients (mean age 67.6 years, range 52–81) with bladder outlet obstruction caused by benign prostatic hyperplasia who received either a SR‐PLA stent (22 patients) and a suprapubic catheter, or a suprapubic catheter only (23 patients) after undergoing VLAP. The suprapubic catheter was removed when voiding started. The response to VLAP and the effect of the stent or catheter were assessed using symptom scores, peak flow rate (Qmax ), post‐void residual volume (PVR), stent degradation, infection and outcome. Results  Voiding started on the first or second day after treatment in 18 (median one day) of 22 patients with a spiral stent and in eight (median 6 days) of 23 patients with only the suprapubic catheter. The mean degradation time of the SR‐PLA stent was 6 months; spiral fragments were found in the prostatic urethra or the urinary bladder in 20 of the patients on cystoscopy. Improvements in patient‐weighted symptom score, mean Qmax and PVR were significant in both groups at the 6 month follow‐up. The infection rate increased with the duration of suprapubic catheterization, from 25% (0–3 days) to 44% (>3 days). Stones were seen in two stented patients during the follow‐up. Conclusion  The SR‐PLA spiral stent is safe and effective for the treatment of post‐operative urinary retention after laser therapy. The degradation time of the stent was unnecessarily long compared with the duration of prostatic swelling and tissue sloughing after laser therapy. The infection rate depends on the duration of suprapubic catheterization.
ISSN:0007-1331
1464-410X
DOI:10.1046/j.1464-410X.1997.00308.x